background image

GENERAL SAFETY WARNINGS

3

BP1219

>

  Before using this product, review and verify that all tools 

  to be used with it have safety equipment installed and 

  are in proper working order as defined by the tool’s 

  owner’s manual.

>

  Do not use this product until you have read and are 

  confident you understand:

 • Digital Height Gauge (pp. 8 - 11); 

  •  Digital Angle Rule (pp. 12 - 14);

  •  Digital Calipers (pp. 15 - 18);

 • Magnetic Angle Gauge (pp. 19 - 22);

>

  The user assumes all risk and responsibility for the proper 

  and safe use of this product and for ensuring product 

  suitability for the intended application.

>

  It is the sole responsibility of the purchaser of this 

  product to ensure that any anyone you allow to use this 

  product reads and complies with all instructions and 

  safety precautions outlined in this manual prior to use.

>

  Follow all standard shop safety practices, including:

  •  Keep children and bystanders away from the tool 

  operating 

area;

  • Do 

NOT

 use power tools in explosive environments, or 

    in the presence of flammable liquids, fumes or dust;

 • 

TURN OFF AND UNPLUG

 all power tools 

BEFORE

 

    making any adjustments or changing accessories;

  •  Remain alert and use good judgment. Do not use this 

    product if you are in any way impaired by medications, 

    alcohol, drugs or fatigue;

  •  Keep your work area well lit and clean;

Continued on page 4...

Содержание 89409

Страница 1: ...uctions prior to use for important safety information Always check Rockler com to confirm that you are using the most recent version of instructions for your product 4 Piece Digital Measuring Kit Effe...

Страница 2: ...product page at Rockler com Before using another tool with this product always read understand and follow the instructions and safety warnings in the owner s manual for that tool If you do not have th...

Страница 3: ...intended application It is the sole responsibility of the purchaser of this product to ensure that any anyone you allow to use this product reads and complies with all instructions and safety precaut...

Страница 4: ...this product ALWAYS wear safety glasses hearing protection and respiratory protection that complies with NIOSH OSHA ANSI safety standards Use dust collection tools and dust face masks to reduce expos...

Страница 5: ...serious injury Warning indicates a hazardous situation that if not avoided could result in death or serious injury Caution indicates a hazardous situation that if not avoided may result in minor or m...

Страница 6: ...are NOT toys This product contains a rare earth neodymium magnet and may affect internal medical devices such as pacemakers Keep away from internal medical devices Batteries can explode or leak if he...

Страница 7: ...e sharp edges Exercise caution in handling Do NOT immerse the digital measuring tools in water Do not use solvents to clean Clean with a soft dry cloth When they re not in use the digital measuring to...

Страница 8: ...122 F 0 C to 50 C Working humidity 85 Button Locations and Functions Fig 1 ON OFF Short single press turns Gauge on in Absolute Mode see below for explanation of modes A second short press sets the d...

Страница 9: ...battery Installing Changing the Battery 1 Pull up on the tab on the top of the digital readout to remove the battery holder Fig 1 2 Remove the old battery and install a new one making sure that the s...

Страница 10: ...the distance the rule is moved 6 To set the Gauge for use lift the center rule to the desired height and tighten the thumbscrew to lock in the setting Do not overtighten the thumbscrew Absolute and I...

Страница 11: ...he digital indicator will switch to 0 Tighten the thumbscrew to secure the setting set the bit height and make the first pass Now loosen the thumbscrew and slide the rule until the digital readout dis...

Страница 12: ...ture 32 F to 122 F 0 C to 50 C Working humidity 85 Button Function Fig 2 ON OFF Short press turns device on Moving the scale also turns on the readout A second short press turns off the device Otherwi...

Страница 13: ...ding from the bottom of the digital readout You will see the top of the battery holder emerge from the top of the digital readout Fig 2 2 Remove the battery holder 3 Remove the old battery and install...

Страница 14: ...with the digital readout anchored on the surface rotate the other rule to the angled surface to determine the angle To measure the angle from the right Turn the device on and place it on edge on the s...

Страница 15: ...N button Short press turns device on another short press turns device off ZERO button Short press sets device to zero at that position Mm inch F button Press to switch measurements between millimeters...

Страница 16: ...Fig 3 Step gauge not visible Depth gauge not visible Inside Jaws Outside Jaws Mm inch F button Locking Screw Battery Cover Thumbwheel ON OFF Button Zero Button 16...

Страница 17: ...ension of a hole dado groove mortise or other opening in a workpiece Fig 5 Step gauge not visible Used to measure between the edge of a workpiece and another point or lip on a workpiece for example me...

Страница 18: ...e Calipers 1 Turn the Digital Calipers on 2 Make sure the calipers are fully closed so that the Thumbwheel won t turn any further 3 Hit the ZERO button once The digital readout should reset to 0 Probl...

Страница 19: ...ght 0 082kg Installing Changing the Battery The Digital Calipers use one AAA alkaline battery We recommend removing the battery before storing the device 1 Make sure the Magnetic Angle Gauge is turned...

Страница 20: ...20 Fig 8 Fig 7 Battery Compartment ON OFF Button Zero Button...

Страница 21: ...other point 1 Push the ON OFF button once to turn on the device To turn off the device press and hold the ON OFF button for 3 seconds Fig 8 2 The device defaults to the Absolute Mode meaning that it r...

Страница 22: ...dropped or the angle reading is obviously incorrect 1 Place the Magnetic Angle Gauge level on a flat surface and press the ON OFF and ZERO buttons simultaneously until 1 appears on the display 2 Press...