Rockford Systems KYL-229 Скачать руководство пользователя страница 4

4

Rockford Systems, LLC—www.rockfordsystems.com 

Call: 1-800-922-7533

SECTION 2—UPPER BELT SANDER SHIELDS

Upper Belt Sander Shield Installation Instructions (continued)

10.  Permanently attach danger signs No. KSC-046

and No. KSC-048 (if furnished). Make sure they

are readily visible to all personnel who work on or

around the machine.

6.  Slide shield arm onto mounting arm and tighten

button-head cap screws.

7. Reattach end cap to bottom of shield arm.

8.  Attach an end cap to each end of mounting arm us-

ing the furnished nylon push-in fasteners.

9.  Use the T-handle knob to adjust the shield up or

down.

5.  Using the mounting arm as a template, mark, drill,

and tap mounting holes and attach the mounting

arm to the machine using the furnished socket-

head cap screws.

Mounting Arm

Shield Arm

Mounting Arm

Содержание KYL-229

Страница 1: ... 815 874 7891 Fax 815 874 6144 Web Site www rockfordsystems com E Mail customerservice rockfordsystems com Manual No KSL 282 INSTALLATION INSTRUCTIONS DISC SANDER SHIELDS UPPER BELT SANDER SHIELDS LOWER BELT SANDER SHIELDS Disc Sander Shields Upper and Lower Belt Sander Shields ...

Страница 2: ...e mounting brackets using the four T nuts and washers 3 Using the mounting arms and shield assembly as a template mark mounting holes where the assembly is to be mounted Drill and tap holes Mount the shield assembly to the machine Use the T handle knobs to adjust the shield up or down 4 Permanently attach danger signs No KSC 046 and No KSC 048 if furnished Make sure they are read ily visible to al...

Страница 3: ...ive cover ing from both sides of the shield if any 2 Attach the polycarbonate shield to the mounting bracket using the T handle knob and hex nut 3 Remove the end cap from bottom of shield arm 4 Loosen the two buttton head cap screws through access holes on shield arm and slide mounting arm from shield arm Set aside Shield MountingArm ShieldArm T HandleKnob HexNut ShieldArm EndCap T Nut MountingArm...

Страница 4: ... who work on or around the machine 6 Slide shield arm onto mounting arm and tighten button head cap screws 7 Reattach end cap to bottom of shield arm 8 Attach an end cap to each end of mounting arm us ing the furnished nylon push in fasteners 9 Use the T handle knob to adjust the shield up or down 5 Using the mounting arm as a template mark drill and tap mounting holes and attach the mounting arm ...

Страница 5: ...move button head cap screws Align holes on shield to end cap insert and tighten button head cap screws 3 Using the mounting arm as a template mark holes where the shield assembly is to be mounted Drill and tap holes Mount the shield assembly to the machine 4 Attach end cap to open end of mounting arm using the furnished nylon push in fasteners 5 Permanently attach danger signs No KSC 046 and No KS...

Страница 6: ... the date of shipment thereof ROCKFORD SYSTEMS LLC S OBLIGATION UNDER THIS WAR RANTY IS EXPRESSLY AND EXCLUSIVELY LIMITED to repairing or replacing such products which are returned to it within the warranty period with shipping charges prepaid and which will be disclosed as defective upon examina tion by Rockford Systems LLC This warranty will not apply to any product which will have been subject ...

Отзывы: