Rockford Systems DM2 D Series Скачать руководство пользователя страница 4

4

Rockford Systems, LLC—www.rockfordsystems.com 

Call: 1-800-922-7533

WARRANTY

Rockford Systems, LLC warrants that this product will be free from defects in material and workmanship for a period 

of 12 months from the date of shipment thereof. ROCKFORD SYSTEMS LLC’s OBLIGATION UNDER THIS WARRANTY 

IS EXPRESSLY AND EXCLUSIVELY LIMITED to repairing or replacing such products which are returned to it within the 

warranty period with shipping charges prepaid and which will be disclosed as defective upon examination by Rockford 

Systems, LLC. This warranty will not apply to any product which will have been subject to misuse, negligence, accident, 

restriction and use not in accordance with Rockford Systems, LLC’s instructions or which will have been altered or 

repaired by persons other than the authorized agent or employees of Rockford Systems, LLC. Rockford Systems, LLC’s 

warranties as to any component part is expressly limited to that of the manufacturer of the component part.

Warranty, Disclaimer and Limitation of Liability

LIMITATION OF LIABILITY

Under  no  circumstances,  including  any  claim  of  negligence, 

strict liability, or otherwise, shall Rockford Systems, LLC be li-

able for any incidental or consequential damages, or any loss 

or damage resulting from a defect in the product of Rockford 

Systems, LLC.

DISCLAIMER

The foregoing Warranty is made in lieu of all other warranties, 

expressed or implied, and of all other liabilities and obligations 

on the part of Rockford Systems, LLC, including any liability for 

negligence, strict liability, or otherwise, and any implied warranty 

of merchantability or fitness for a particular purpose is expressly 

disclaimed.

NATIONAL SAFETY COUNCIL SAFETY MANUALS
Other good references for safety on machine tools are the 

National Safety Council’s Safety Manuals. These manu-

als are written by various committees including the Power 

Press,  Forging  and  Fabricating  Executive  Committee. 

Copies  of  the  following  publications  are  available  from 

their library:

• Power Press Safety Manual - 5th Edition

• Safeguarding Concepts Illustrated - 7th Edition

• Forging Safety Manual

These manuals can be obtained by contacting:

National Safety Council

1121 Spring Lake Drive

Itasca, IL 60143-3201

1-800-621-7615

www.nsc.org

OTHER SAFETY SOURCES
National  Institute  of  Occupational  Safety  and  Health 

(NIOSH)

4676 Columbia Parkway

Cincinnati, OH 45226

Toll-Free: 1-800-35-NIOSH (1-800-356-4674)

Phone: (513) 533-8328

www.cdc.gov/niosh

OTHER SAFETY SOURCES (CONTINUED)

Robotic Industries Association (RIA)

900 Victors Way, Suite 140

P.O. Box 3724

Ann Arbor, MI 48106

Phone: (734) 994-6088

www.roboticsonline.com

NEMA (National Electrical Manufacturers 

Association)

1300 North 17th Street, Suite 1847

Rosslyn, VA 22209

Phone: (703) 841-3200

www.nema.org

NFPA (National Fire Protection Association)

1 Batterymarch Park

Quincy, MA 02269-9101

Phone: (617) 770-3000

www.nfpa.org

For additional safety information and assistance in devis-

ing, implementing or revising your safety program, please 

contact the machine manufacturer, your state and local 

safety  councils,  insurance  carriers,  national  trade  asso-

ciations and your state’s occupational safety and health 

administration.

SECTION 1—IN GENERAL

DM

2

 Series D Dual-Solenoid Valves

Содержание DM2 D Series

Страница 1: ...874 7891 Fax 815 874 6144 Web Site www rockfordsystems com E Mail customerservice rockfordsystems com Manual No KSL 288 INSTALLATION MANUAL FOR DM2 SERIES D DUAL SOLENOID VALVES IMPORTANT PLEASE REVIE...

Страница 2: ...ions which must be conveyed to your personnel and incorporated in to your program include DANGER Never place your hands or any part of your body in this machine Never operate this machine without prop...

Страница 3: ...ov ANSI SAFETY STANDARDS FOR MACHINES The most complete safety standards for machine tools are published in the ANSI American National Standards Institute B11 series The following is a list of each AN...

Страница 4: ...lity for negligence strict liability or otherwise and any implied warranty of merchantability or fitness for a particular purpose is expressly disclaimed NATIONAL SAFETY COUNCIL SAFETY MANUALS Other g...

Страница 5: ...ring of the valve detects this failure and thereby exhausts downstream air locks out the valve and prohibits further operation When a valve lockout occurs the valve will retain the fault information r...

Страница 6: ...pacity Teflon back up rings on pistons to enhance valve endurance operates with or without inline lubrication Status Indicator Optional Includes a pressure switch with both normally open and normally...

Страница 7: ...ed in overall hole dimnsions at left 0 22 5 6 4 places 4 00 101 6 4 00 101 6 0 25 6 4 2 04 51 9 4 79 121 6 1 19 30 2 0 82 20 9 1 37 34 9 9 99 253 8 With Status Indicator 4 50 114 3 4 00 101 6 0 25 6 4...

Страница 8: ...olenoid Sizes 2 4 12 30 For primary and reset solenoids 6 0 watts on DC 15 8 VA inrush and 10 4 VA holding on AC Size 8 Primary solenoids 15 watts on DC 36 VA inrush and 24 6 VA holding on AC Reset so...

Страница 9: ...olenoid valve Optional Status Indicator VALVE SCHEMATIC EXHAUST OUTLET INLET A B Pilot Valve B Pilot Valve A Pilot supply timing chamber A Piston Outlet chamber Inlet poppet Timing orifice Flow restri...

Страница 10: ...pilot air available to actuate but has full pressure on the inlet poppet and return piston to hold the element in the fully closed position Inlet air flow on side A into its crossover is restricted a...

Страница 11: ...ct performance and shorten valve life Pipe Installation To install pipe in base ports engage the pipe by one turn then apply pipe thread sealant tape not recommended and tighten pipe This procedure wi...

Страница 12: ...normally open contact N C contact held open with normal operation and inlet pressure within specifications Ground symbol terminal not used Terminals 1 and 3 are connected when air pressure is present...

Страница 13: ...solenoids are de energized removal of reset signal will return the valve to the ready to run mode An additional test to perform With the valve in the ready to run mode exhaust and re pressurize the in...

Страница 14: ...contact the oil manufacturer for compatibility information Cleaning the Valve If the air supplied to the valve has not been well filtered the interior of the valve may accumulate dirt and varnish whi...

Страница 15: ...ual valves with remote reset require a small reset valve and the installation of a 1 8 line from the reset valve to the reset port This air pushbutton is suitable for this purpose CAUTION Do not use e...

Страница 16: ...m Description Size 2 Size 4 Size 8 Size 12 Size 30 110VAC 24VDC A Valve body service kit RCY 300 RCY 301 RCY 302 RCY 303 RCY 304 n a n a B Complete primary solenoid pilot RCY 305 RCY 306 RCY 307 RCY 3...

Страница 17: ...elds For Machinery For prices and delivery please use address phone or fax number listed on the front cover of this manual Your Signature Date SECTION 11 RETURN MATERIALS AUTHORIZATION REQUEST FORM SE...

Страница 18: ...5795 Logistics Parkway Rockford Illinois 61109 Toll Free 1 800 922 7533 Phone 815 874 7891 Fax 815 874 6144 customerservice rockfordsystems com www rockfordsystems com KSL 288 RS 0619...