OSHA ACT AND FEDERAL REGULATIONS
Since the enclosed equipment can never overcome a me-

chanical deficiency, defect or malfunction in the machine 

itself, OSHA (Occupational Safety and Health Administra-

tion)  has  established  certain  safety  regulations  that  the 

employers (users) must comply with so that the machines 

used in their plants, factories or facilities are thoroughly 

inspected and are in first-class operating condition before 

any of the enclosed equipment is installed.
1 .   U .S . Government—An Act—Public Law 91-596, 

91st Congress, S. 2193, December 29, 1970:

 Duties

SEC. 5. (a) Each employer—
(1)  shall  furnish  to  each  of  his  employees  employ-

ment and a place of employment which are free

from recognized hazards that are causing or are

likely to cause death or serious physical harm to

his employees;

(2)  shall comply with occupational safety and health

standards promulgated under this Act.

(b)  Each  employee  shall  comply  with  occupational

safety and health standards and all rules, regu-

lations,  and  orders  issued  pursuant  to  this  Act

which are applicable to his own actions and con-

duct.

2.  OSHA 29 CFR Sections that an employer (user)

must comply with include:
1910.211 Definitions.
1910.212 General requirements for all machines.
1910.217 Mechanical power presses.
1910.219 Mechanical power-transmission apparatus.

3 .   OSHA 29 CFR 1910 .147 The control of hazardous 

energy (lockout/tagout).

4 .  OSHA Publication

 “General Industry Safety and Health Regulations Part 

1910,” Code of Federal Regulations, Subpart O
This publication can be obtained by contacting:

U.S. Government Printing Office

P.O. Box 371954

Pittsburgh, PA 15250-7954

Phone: (202) 512-1800

http://bookstore.gpo.gov

ANSI SAFETY STANDARDS FOR MACHINES
The  most  complete  safety  standards  for  machine  tools 

are published in the ANSI (American National Standards 

Institute) B11 series. The following is a list of each ANSI 

B11 Standard available at the printing of this publication.
B11–2008  General Safety Requirements

B11.1 

Mechanical Power Presses

B11.2 

Hydraulic Power Presses

B11.3 

Power Press Brakes

B11.4 

Shears

B11.5 

Iron Workers

B11.6 

Lathes

B11.7 

Cold Headers and Cold Formers

B11.8 

Drilling, Milling, and Boring Machines

B11.9 

Grinding Machines

B11.10 

Metal Sawing Machines

B11.11 

Gear and Spline Cutting Machines

B11.12 

Roll Forming and Roll Bending Machines

B11.13 

Automatic Screw/Bar and Chucking Machines

B11.14 

Withdrawn (Now see ANSI B11.18)

B11.15 

Pipe, Tube and Shape Bending Machines

B11.16 

Metal Powder Compacting Presses

B11.17 

Horizontal Hydraulic Extrusion Presses

B11.18 

Coil Processing Systems

B11.19 

Performance Criteria for Safeguarding

B11.20 

Integrated Manufacturing Systems

B11.21 

Lasers

B11.22 

CNC Turning Machines

B11.23 

Machining Centers

B11.24 

Transfer Machines

B11.TR1  Ergonomic Guidelines

B11.TR2  Mist Control Considerations

B11.TR3  Risk Assessment

B11.TR4  Programmable Electronic Systems (PES/PLC)

B11.TR5  Sound Level Measurement Guidelines

B11.TR7  Risk Assessment

R15.06 

Robotic Safeguarding

B15.1 

Mechanical Power Transmission Apparatus

B56.5 

 Guided  Industrial  Vehicles  and  Automated 

Function of Manned Industrial Vehicles

B65.1 

Printing Press Systems

B65.2 

Binding and Finishing Systems

B65.5 

Stand-Alone Patten Presses

B151.1 

Horizontal (Plastic) Injection Molding Machines

B152.1 

Hydraulic Die Casting Presses

B154.1 

Rivet Setting Machines

B155.1 

Packaging Machinery

01.1 

Woodworking Machinery

These standards can be purchased by contacting:

ANSI—American National Standards Institute

25 West 43rd Street, 4th Floor

New York, New York 10036

Phone: (212) 642-4900

www.ansi.org

SECTION 1—IN GENERAL

DM

2

 Series D Dual-Solenoid Valves

Содержание DM2 D Series

Страница 1: ...874 7891 Fax 815 874 6144 Web Site www rockfordsystems com E Mail customerservice rockfordsystems com Manual No KSL 288 INSTALLATION MANUAL FOR DM2 SERIES D DUAL SOLENOID VALVES IMPORTANT PLEASE REVIE...

Страница 2: ...ions which must be conveyed to your personnel and incorporated in to your program include DANGER Never place your hands or any part of your body in this machine Never operate this machine without prop...

Страница 3: ...ov ANSI SAFETY STANDARDS FOR MACHINES The most complete safety standards for machine tools are published in the ANSI American National Standards Institute B11 series The following is a list of each AN...

Страница 4: ...lity for negligence strict liability or otherwise and any implied warranty of merchantability or fitness for a particular purpose is expressly disclaimed NATIONAL SAFETY COUNCIL SAFETY MANUALS Other g...

Страница 5: ...ring of the valve detects this failure and thereby exhausts downstream air locks out the valve and prohibits further operation When a valve lockout occurs the valve will retain the fault information r...

Страница 6: ...pacity Teflon back up rings on pistons to enhance valve endurance operates with or without inline lubrication Status Indicator Optional Includes a pressure switch with both normally open and normally...

Страница 7: ...ed in overall hole dimnsions at left 0 22 5 6 4 places 4 00 101 6 4 00 101 6 0 25 6 4 2 04 51 9 4 79 121 6 1 19 30 2 0 82 20 9 1 37 34 9 9 99 253 8 With Status Indicator 4 50 114 3 4 00 101 6 0 25 6 4...

Страница 8: ...olenoid Sizes 2 4 12 30 For primary and reset solenoids 6 0 watts on DC 15 8 VA inrush and 10 4 VA holding on AC Size 8 Primary solenoids 15 watts on DC 36 VA inrush and 24 6 VA holding on AC Reset so...

Страница 9: ...olenoid valve Optional Status Indicator VALVE SCHEMATIC EXHAUST OUTLET INLET A B Pilot Valve B Pilot Valve A Pilot supply timing chamber A Piston Outlet chamber Inlet poppet Timing orifice Flow restri...

Страница 10: ...pilot air available to actuate but has full pressure on the inlet poppet and return piston to hold the element in the fully closed position Inlet air flow on side A into its crossover is restricted a...

Страница 11: ...ct performance and shorten valve life Pipe Installation To install pipe in base ports engage the pipe by one turn then apply pipe thread sealant tape not recommended and tighten pipe This procedure wi...

Страница 12: ...normally open contact N C contact held open with normal operation and inlet pressure within specifications Ground symbol terminal not used Terminals 1 and 3 are connected when air pressure is present...

Страница 13: ...solenoids are de energized removal of reset signal will return the valve to the ready to run mode An additional test to perform With the valve in the ready to run mode exhaust and re pressurize the in...

Страница 14: ...contact the oil manufacturer for compatibility information Cleaning the Valve If the air supplied to the valve has not been well filtered the interior of the valve may accumulate dirt and varnish whi...

Страница 15: ...ual valves with remote reset require a small reset valve and the installation of a 1 8 line from the reset valve to the reset port This air pushbutton is suitable for this purpose CAUTION Do not use e...

Страница 16: ...m Description Size 2 Size 4 Size 8 Size 12 Size 30 110VAC 24VDC A Valve body service kit RCY 300 RCY 301 RCY 302 RCY 303 RCY 304 n a n a B Complete primary solenoid pilot RCY 305 RCY 306 RCY 307 RCY 3...

Страница 17: ...elds For Machinery For prices and delivery please use address phone or fax number listed on the front cover of this manual Your Signature Date SECTION 11 RETURN MATERIALS AUTHORIZATION REQUEST FORM SE...

Страница 18: ...5795 Logistics Parkway Rockford Illinois 61109 Toll Free 1 800 922 7533 Phone 815 874 7891 Fax 815 874 6144 customerservice rockfordsystems com www rockfordsystems com KSL 288 RS 0619...