SECTION 8—REPLACEMENT PROCEDURES
SSC-1500 Gen II Part-Revolution Solid-State Control
All power to the machine must be off before
replacing the control module or any other parts.
1. Locate the control module inside the control box.
2. Remove all terminal strips from the left and right sides of the
circuit board. Unplug the main power cord from the left side of
the module. See Photo 8.1.
3. Loosen the four Allen-head bolts (Photo 8.2) and lift up on the
control module. Pull the unit straight out. See Photo 8.3.
4. Remove the four small screws from the cover of the control
module (Photo 8.4) and lift the cover straight up.
5. Remove the eight small screws from the circuit board (Photo
8.5) and lift the circuit board straight up.
6. Locate the core module in the center of the circuit board.
Remove the small screw and lift the core module out by gently
wiggling it back and forth. Keep track of the nylon spacer.
7. Insert the new core module onto the circuit board keeping the
nylon spacer in place. See Photo 8.6. Tighten the screw.
8. Place the circuit board back on the control module and secure
it with the eight screws.
9. Place the cover back on the control module and secure it with
the four screws.
10. Put the control module back in place, tighten the Allen-
head bolts, plug in the main power cord, and insert all
terminal strips.