Rockford Fosgate RFC10HB Скачать руководство пользователя страница 8

8

S

PECIFICATIONS

MODEL- 

10 Farad Hybrid Capacitor

RFC10HB

Rated Capacitance

– 77°F (25°C)

10 Farad

(Constant Current Discharge (5A) 15.0v–>3.0v)

Capacitance Tolerance

±10%

Rated Voltage,VR

16.0 Volts

Surge Voltage

18.0 Volts

Maximum Internal Resistance

(ESR):

<6.5m

Operating Temperature  Range*

-40 to 140°F

(-40 to 60°C)

Storage Temperature  Range

-40 to 158°F

(-40 to 70°C)

Input/Output Connections

(6) 1/0 AWG and/or 4 AWG

(AWG-American Wire  Gauge)

Dimensions:

Height

2.25" (5.72cm)

Width

10.25" (26.04cm)

Length

6.5" (16.51cm)

Weight:

3.31 lbs. (1.5kg)

*

Prolonged operation above the operating temperature limit of a cell will greatly reduce its useful life

span. Exposure to temperatures below the operating temperature will reduce the ability of the cell to
easily accept a charge.

Specifications subject to change without notice

I

NSTALLATION

DISPOSING OF HYBRID CAPACITOR CELLS

A Rockford Hybrid Capacitor cell contains hazardous material, such as Acetonitrile (ACN).You must
follow federal, state, and local laws when disposing of failed or aged cells. For more information, contact
the Customer Support department of Rockford Corp. 1-800-669-9899. Capacitor modules that have
reached their end-of-life can be recycled. Rockford Corp. will take back capacitor modules that need to 
be recycled. Rockford does not pay for shipping of returned capacitor modules that are to be recycled.

CAUTION:

To prevent injury due to hazardous chemicals, do not touch the capacitor if

the safety vent has ruptured. Have the system looked at 
by a qualified technician for repair and/or disposal.

Содержание RFC10HB

Страница 1: ...Installation Operation RFC10HB 10 FARAD HYBRID CAPACITOR Serial Number Date of Purchase ...

Страница 2: ...itical charge and discharge rates What makes Rockford Hybrid Capacitor Cells so special The electrode forming process which produces ultra dense yet porous hybrid electrodes and the continuous operating voltage of 2 7 volts per cell give the Rockford Hybrid Capacitor the highest energy storage capacity and power density of any other commercially available components of comparable size and weight T...

Страница 3: ... been properly discharged before servicing the vehicle and or system components CAUTION Failure to observe the following safety precautions could result in damage to the capacitor vehicle and or personal injury DO NOT allow metal objects such as screwdrivers or other tools to touch both capacitor terminals at the same time The result may cause arcing and possible fire DO NOT use capacitor cells th...

Страница 4: ...ce ESR characteristic of Rockford s Hybrid Capacitor enables them to supply large amounts of instantaneous peak power when demanded by the load Long Life Rockford s Hybrid Capacitor has a very long life span as well They have been subjected to more than 500 000 charge and discharge cycles and only show a small typical loss of capacitance less than 20 and an even smaller than typical increase in ES...

Страница 5: ...m from damage with proper fusing Install the appropriate fuse holder and fuse on the 12V power wire within 18 45 7 cm of the battery terminal 10 When grounding to the chassis of the vehicle scrape all paint from the metal to ensure a good clean ground connection Grounding connections should be as short as possible and always be connected to metal that is welded to the main body or chassis of the v...

Страница 6: ...wires are visible Ensure all wires are secured Loose connections will affect the performance of your capacitor possibly leading to failure 3 To hook up your amplifier or distribution block use the available 1 0 AWG and or 4 AWG connections 4 Mount the unit securely in the location decided upon Charging and connecting the Hybrid Capacitor to the battery ATTENTION Charging your capacitor will ensure...

Страница 7: ...iliary form of power is hooked up It is very very important that the capacitor module be discharged before performing any kind of service on the vehicle It is important to remember that your Rockford Hybrid Capacitor could still be fully charged and could cause personal injury if not discharged 8 The Rockford Hybrid Capacitor is now ready for use Discharging the Hybrid Capacitor WARNING To prevent...

Страница 8: ...ating temperature will reduce the ability of the cell to easily accept a charge Specifications subject to change without notice INSTALLATION DISPOSING OF HYBRID CAPACITOR CELLS A Rockford Hybrid Capacitor cell contains hazardous material such as Acetonitrile ACN You must follow federal state and local laws when disposing of failed or aged cells For more information contact the Customer Support dep...

Страница 9: ... Covered 1 Damage caused by accident abuse improper operations improper wiring water theft 2 Any cost or expense related to the removal or reinstallation of product 3 Service performed by anyone other than Rockford or an Authorized Rockford Fosgate Service Center 4 Any product which has had the serial number defaced altered or removed 5 Subsequent damage to other components 6 Any product purchased...

Страница 10: ...10 NOTES ...

Страница 11: ...11 NOTES ...

Страница 12: ...ration 546 South Rockford Drive Tempe Arizona 85281 U S A In U S A 480 967 3565 Customer Service 1 800 669 9899 In Europe Fax 49 8503 934014 In Japan Fax 81 559 79 1265 www rockfordfosgate com 04 07 B M 1230 53683 02 Printed in China ...

Отзывы: