4
I
NSTALLATION
INSTALLATION CONSIDERATIONS
The following is a list of tools needed for installation:
Volt/Ohm Meter
Wire strippers
Wire crimpers
Wire cutters
Felt-tip pen or center punch
#2 Phillips screwdriver
3/16” Allen wrench
5/32” Allen wrench
Battery post wrench
Hand held drill w/assorted bits
Electrical tape
Rubber or snap grommets
Nylon tie straps
Assorted connectors
Adequate Length—Red Power Wire
Adequate Length—Black Grounding Wire
D
ESIGN
F
EATURES
The following features are the results of the unique patented manufacturing process that enables the
Rockford Hybrid Capacitor to deliver many charge and discharge cycles with greater energy and power
per unit weight and volume.
High Energy
The amazingly high specific capacitance and lower weight of Rockford's Hybrid Capacitor yields an energy
per kilogram figure that is twice that of any other commercially available Electric Double Layer Capacitor
(EDLC).
More Power
Both the 'per weight' and 'per volume' power density of Rockford's Hybrid Capacitor exceeds that of
other hybrid capacitors in production today.The extremely low internal resistance (ESR) characteristic of
Rockford's Hybrid Capacitor enables them to supply large amounts of instantaneous peak power, when
demanded by the load.
Long Life
Rockford's Hybrid Capacitor has a very long life span as well.They have been subjected to more than
500,000 charge and discharge cycles and only show a small typical loss of capacitance (less than 20%) and
an even smaller than typical increase in ESR (less than 2X).The long life span of the Rockford's Hybrid
Capacitor means that it may never need to be replaced.
Excellent Low Temperature Performance
Rockford's Hybrid Capacitors show very little loss of effective capacitance or ESR, even at temperatures as
low as -°40F (-°40C).
SAFETY FEATURES
LED Display
The display at the top of the Rockford Hybrid Capacitor will show the current voltage at the capacitor.
Warning Buzzer
The warning buzzer will sound if the Rockford Hybrid Capacitor has been wired to a reverse polarity.
Safety Vent
The safety vent ruptures when the internal pressure of capacitor cell has reached 5 ~ 10 kg/cm2.
CAUTION:
To prevent injury due to hazardous chemicals, do not touch the capacitor
if the safety vent has ruptured. Have the system looked at by a qualified
technician for repair and/or disposal.
ATTENTION:
Safety vent ruptures caused by improper wiring is not covered under
warranty.
Содержание RFC10HB
Страница 1: ...Installation Operation RFC10HB 10 FARAD HYBRID CAPACITOR Serial Number Date of Purchase ...
Страница 10: ...10 NOTES ...
Страница 11: ...11 NOTES ...