7
Need help? Call 800-620-2790
RF-TVMLPT02V2 TV Wall Mount
STEP 2 -
Option 2: Installing on a solid concrete or concrete block wall
CAUTION
: To prevent property damage or personal injury, never drill into mortar between blocks. Mount wall
plate directly onto the concrete surface.
1
Align the wall plate template (
D
) at the height you determined in the previous step and make sure that it is
level. Tape the wall plate template (
D
) to the wall, then use a pencil to mark the lag bolt hole locations (3).
Remove the template (
D
).
2
Drill pilot holes to a depth of 3 in. (75 mm) using a 3/8 in. (10 mm) diameter masonry drill bit.
3
Insert the concrete wall anchors (
S
) into the pilot holes and use a hammer to make sure the anchors are flush
with the concrete surface.
4
Align the wall plate (
A
) with the anchors, insert the lag bolts (
R
) through the lag washers (
Q
) and the holes in
the wall plate, then tighten the lag bolts only until they are firm against the wall plate.
CAUTION
: Avoid potential injuries or property damage!
DO NOT over-tighten the lag bolts (
R
).
You’ll need
Center pencil mark
made in Step 1.
3 in.
(75 mm)
Note
: Minumum solid concrete thickness: 8 in (203
mm). Minimum concrete block size: 8 x 8 x 16 in.
(203 x 203 x 406 mm).
Q
(3)
R
(3)
Pencil
Drill
3/8" masonry
drill bit
1/2" socket
wrench
Level
Tape
S
(3)
(
D
) Template
Top
Dessus
Parte superior
Top
Dessus
Parte superior
RF-TVMLPT02V2
Template • Gabarit • Plantilla
Note
: For wood frame installations, use a stud
finder to locate wood studs first.
Remarque
: Pour une construction à ossature
de bois, localiser d'abord les montants en bois,
à l'aide d'un détecteur de montants.
Nota
: para la instalación en construcciones de
armazón de madera, primero debe localizar las
vigas de madera con un localizador de vigas.
Need help deciding how high to mount your TV? Scan this QR code.
Besoin d'aide pour déterminer la hauteur de montage du téléviseur?
Numériser ce code QR.
¿Necesita ayuda para determinar la altura de montaje de su
televisor? Escanee este código QR.
V2 13-0195
Tools Needed
Outils nécessaires
Herramientas requeridas
Wall plate (
A
)
Hammer
Note
: The minumum
distance between the
top two fasteners
cannot be less than 5 in.
(127 mm).
RF-TVMLPT02V2_13-0194_MAN_V2_EN - GIFs.fm Page 7 Thursday, March 14, 2013 12:01 PM