Rocker BioVac 225 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BioVac 225 

BioVac 225 Plus 

BioVac 225 - BioDolphin 

 

Portable suction system 

 

Содержание BioVac 225

Страница 1: ...BioVac 225 BioVac 225 Plus BioVac 225 BioDolphin Portable suction system ...

Страница 2: ...ce Before using the instrument please ensure that the power supply voltage matches the voltage rating for the instrument Please ensure that all connections are well sealed The disc filter needs to be replaced periodically or immediately once it is contaminated or saturated The built in thermal protector will shut down the instrument automatically when it gets too hot Please check the fuse if the i...

Страница 3: ...C Portable Suction System Diagram pic 1 BioVac 225 pic 2 BioVac 225 Plus pic 3 BioVac 225 BioDolphin ...

Страница 4: ...5 BioDolphin Item Description 1 BioVac 225 suction unit 2 Disc filter 3 Suction bottle 4 Tube connection adaptor 5 2m silicone tube 6 Handle 7 1 channel tip adaptor with ejector 8 8 channel tip adaptor with ejector 9 1 channel tip adaptor 150 mm 10 Repair kit of handle Item Description 1 BioVac 225 suction unit 2 Disc filter 3 Suction bottle 4 Tube connection adaptor 5 2m silicone tube 6 BioDolphi...

Страница 5: ...use 3 On Off switch 4 Vacuum indicator 5 Vacuum regulator 6 Vacuum pump inlet 7 Suction bottle outlet 8 Suction bottle inlet pic 7 BioVac 225 suction unit and suction bottle part list pic 8 Overflow protection Item Description 1 Overflow protection ...

Страница 6: ...ton 4 Handle end pic 9 Handle part list pic 10 Handle Disassembly pic 11 Operating of 8 channel tip adaptor with ejector pic 12 Change different tip adaptor item Description 1 Rubber adaptor 2 O ring AS004 3 O ring P7 4 Rubber valve 5 S S spring 6 O ring AS012 ...

Страница 7: ...ance with the applicable regulations h Proceed with cleaning and maintenance after every use Note Check the liquid level of the waste bottle before each use and then empty it as per the applicable regulations 2 BioVac 225 Plus pic 2 a Ensure that the overflow protection is installed properly then place the suction bottle on the holder Please refer to pic 9 when installing it Note please always put...

Страница 8: ...mm can be plugged into handle directly for waste suction of microplate or culture dish by pressing the suction button or pressing lock button to keep a continuous operation f The 1 channel tip adaptor is recommended to be plugged into the handle then have it connect with 200 µl disposable tip with which to prevent cross contamination in common microplate and culture dish g For 96 well microplate E...

Страница 9: ...are consumables please replace at least every half year to ensure sufficient air flow G Troubleshooting Symptoms Possible causes and Solution Device fails to start 1 Check the power supply conform to power specified on main unit 2 Blown fuse replace fuse if it is burnt out 3 Check if the power switch is in the ON position 4 Vacuum still exists in system release vacuum and restart 5 Defective switc...

Страница 10: ...lue 199120 00 BioDolphin P Suction kit pink 199130 00 BioDolphin G Suction kit green 199100 30 Handle 199100 46 1 channel tip adaptor 199100 47 1 channel S S adaptor 40 mm 199100 48 1 channel S S adaptor 80 mm 199100 49 8 channel S S adaptor 40 mm 199100 50 8 channel tip adaptor with ejector 199100 75 1 channel tip adaptor with ejector 199100 76 1 channel tip adaptor 150 mm 199100 61 Rack 199100 5...