7
Models ATHENA RV/M and RV/S
have an inner well to place GN pans and an outside well
where the refrigeration components are placed. In case some maintenance is required, in order
to reach the evaporator and the fan-cooling system please refer to the below drawing.
Ref.
Code
Quantity
Description
1
1
Inner well
2
1
False bottom
3
C0500VENTOLA (4 RV-M)
C0500VENTOLA3 (3 RV-M)
1
Fan
4
C0500EVAP
2
Evaporator
5
D04INRDEF
2
Defrost heating element
Always be sure to shut down and unplug the buffet trolley before any kind of
maintenance work. Maintenance must always be done by qualified personnel; the
manufacturer is not responsible for any personal injury that may occur from an
inappropriate maintenance.