1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace’s body.
2.
Heat-resistant spray paint for touch-ups.
3.
Counterweights
4.
Bag with: metal clamp, 2x screws, 2x nuts and adhesive rope.
5.
Tool for handling registers and opening door.
6.
Connector support, air inlet cover and screws.
7.
Heat-resistant glove.
8.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
9.
Bag with screws and washers.
10.
4x Adjustable foots
11.
Cleaning cloth.
12.
Air connectors of
ᴓ
120 mm.
13.
Fume exhaust connector.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
Parameter
Modelo
G 450 DC
Minimum - Maximum draught (Pa)
11-13
Fuel consumption (kg/h)
4,05
Smoke mass flow rate (g/s)
15,24
Performance (%)
82 %
Potencia nominal (kW)
14,8
Rango de potencia (kW)
10-17,5
Average CO concentration at 13% of O
2
: (mg/Nm
3
)
0,12
Average NO
x
concentration at 13% of O
2
: (mg/Nm
3
)
91,11
Average OGC concentration at 13% of O
2
: (mg/Nm
3
)
71,88
Particle concentration at 13% of O
2
: (mg/Nm
3
)
29,47
Medium draft ( trial Pa )
12 Pa
Net weight (kg)
232
Maximum authorized load (fuel - kg)
6
Reload height (mm)
200
Logs length (mm)
550
Minimum flue height (mm)
4000
Ø Flue duct (mm)
250
Ø Air inlet (mm)
120
Ø Hot air outlet (mm)
120
Inner fireplace room safety distances (base) (mm)
Se debe aislar
Inner fireplace room safety distances (back) (mm)
20
Inner fireplace room safety distances (sides) (mm)
20
Outer fireplace safety distances (back) (mm)
1300
Outer fireplace safety distances (sides) (mm)
200
Outer fireplace safety distances (frontal) (mm)
1300
Fireplace room ventilation (entry – exit) (cm
2
)
450
Minimum safety distance to hot air outlets (mm)
250
Average temperature of smoke (ºC)
189
Type of combustión
INTERMITENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20 % - two years under cover
Certification year
2019
Certificate number
19/20678-1858-1 | 19/20678-1858-2
2. REQUIREMENTS PRIOR TO INSTALLATION
Содержание G 450 DC
Страница 38: ...1 ANEXO ANNEX ANNEXE ANESSO I...
Страница 39: ...2 II 1 10 11 9 4 2 5 3 6 7 8 13 12...
Страница 40: ...3 III 1 2...
Страница 41: ...4 III 1 2 3 4 5 6...
Страница 42: ...5 III 7 8 8 A 1 A 2 A 3...
Страница 43: ...6 III A 5 B 1 B 2 B 3 B 4 B 5...
Страница 44: ...7 III B 6 B 7 B 8 C 1 C 2...
Страница 45: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...
Страница 46: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...
Страница 47: ...10 D 13...