Below is a table of possible anomalies, their causes and solutions:
PROBLEM
CAUSE
SOLUTION
1. Rejects smoke
and
/
or
insufficient
draught
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply.
Simultaneous operation with other ventilation devices and / or
heating
Setting the register
2. Excessive dirt
on glass
Incorrect duct
Inappropriate fuel
Overly closed registers
Revise section on insufficient flue
(below).
Use recommended fuel
Adjust registers
3. Glass
bleaching or
colour fading of
the plate
Excessive temperature caused
by excessive heat in the
combustion chamber
Check the fuel load avoiding overheating
Adjust registers
4. Poor heating
Inappropriate fuel
Insufficient load
Combustion control registers in
the wrong position
Use recommended fuel
Adding fuel
Adjust registers
5. Venting smoke
and / or gases
from the front,
bad smell
First lighting
Flammable or combustible items
in the enclosure or surrounding
walls of the equipment
Crack
in
the
combustion
chamber of the equipment
Wait for the polymerization process of the paint to finish; this
can take from one to several lightings.
Review of insulating materials such as fiberglass, fireproof
wood or any inflammable elements and replace them.
Check for tightness and if you discover a crack, please contact
your dealer.
6. Excessive draft Incorrect duct
Combustion control registers in
the wrong position
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
7. Poor draft
Incorrect duct
Duct dirtiness
Open the primary and secondary register following the steps
outlined in the manual. Should this not have an effect, check
that the flue duct is clean; if it is not clean, contact a professional
to clean this. If the problem persists contact your dealer.
6. PROBLEMS: CAUSE AND SOLUTION