9
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner.
It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter.
The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations
. This Flue liner should not be shared with other devices (see Table 1.1
Technical specifications).
2.3 Type of appliance
“Vermiculite” home plate at the bottom, sides and baffle plate. The fireplace comes ready to install. All the
inner can be removed if desired, for easier transportation and installation.
2.4. Insulating procedures.
2.4.1. Apparatus insulation.
The fireplace must be insulated with insulation panels (Type A-1, EN13501-1) on its sides, back and
upper part.
2.4.2 Fireplace room insulation.
It is also convenient to use insulation panels on the inner walls of the fireplace (Type A-1, EN13501-
1).
2.5. Safety distances.
2.5.1. Inner fireplace room safety distances.
You must be respected the values described in 1.1 Technical characteristics.
2.5.2. Outer fireplace safety distances.
Anything fragile or flammable (textile, electronics, wood, paper wall, glass, chalk…) should
be separated of the appliance and respected the safety distances described in 1.1 Technical characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent and avoid the possibility of hot air that
expels the device falls directly on the wood, in these cases, flammable items should be properly insulated.
2.6 Fireplace room.
Fireplace room must be built with non-combustible materials and should not rest on the apparatus and the points
of contact (such as the front frame). Inside should not contain flammable or fragile materials such as wood, wallpaper, glass, chalk
paper, etc.).
2.7. Ventilation.
It is imperative that the niche where the appliance is installed ventilation available.
2.7.1. Fireplace room ventilation.
The appliance must be provided with an air outlet or inlet diffusers for sufficient air flow as
described in Technical characteristics
2.7.2 Air supply.
Air should be provided to the room where the appliance is installed. This is especially relevant when outside air is
not used and also when the door is opened for reloading with logs. This entry cannot be less than 225 cm2. Also note the simultaneous
operation with other ventilation devices and / or heating such as exhaust fans, heat pumps, etc. In these cases, the extraction must
be compensated with a corresponding air entry from outside.
2.8 Changes to the device.
Any intended change to the equipment must be authorized in writing by Manufacturas Rocal, S.A. We
also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3.1 Installation process.
To proceed with the installation, follow the steps outlined in Section III of the ANNEXED document.
WARNING:
The second part of the deflector shield must be adjusted in case there is an excessive draught, follow the steps ‘D.8’ to
‘D.11’. To adjust the door lock, follow the steps ‘D.12’ and ‘D.13’. To change the door opening, follow the steps described in the
images ‘D.14’ to ‘D.21’.
For the painting and finishing of the firebox enclosure, tapes or protectors are used for areas that are not painted, these tapes MUST
NOT TOUCH THE SHEET OF THE APPLIANCE in any case to prevent that the painting might peel off when removing this tapes or
protectors.
It is recommended to remove the frame before closing the firebox or use a protector that does not contain adhesive.
4.1 Fuels authorized by the manufacturer.
The appliance should not be used as an incinerator and the use of fuels other than
those authorized by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs are authorized as fuel
and
it is not advisable to use resinous woods.
4.2 Pilot fire lighting.
For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum load allowed
by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed inside (such as gloves,
spray paint ...)
4.3. Combustion control.
The appliance has mechanisms to regulate combustion.
3. INSTALLATION
4
. USE AND OPERATION
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the height of the
reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a protection glove.
Содержание ARc DC 100
Страница 34: ...33 II 1 2 3 4 5 6 7 8 9 10 ...
Страница 35: ...34 III 1 2 ...
Страница 36: ...35 III 1 2 3 A B A 1 ...
Страница 37: ...36 III A 2 A 3 A 4 A 5 B 1 B 2 ...
Страница 38: ...37 III B 3 Plus 180 B 3 B 4 B 5 ...
Страница 39: ...38 IV D 1 D 2 D 3 D 4 D 5 D 6 ...
Страница 40: ...39 IV D 7 D 8 D 9 D 10 D 11 D 12 ...
Страница 41: ...40 III IV D 13 D 14 D 15 D 16 D 17 D 18 ...
Страница 42: ...41 IV D 19 D 20 D 21 D 22 D 23 D 25 ...
Страница 44: ...43 ...