background image

Robustel GoRugged M1000 UP User Guide 

 

 
RT_UG_M1000 UP_v.1.1.1 

07.10.2015 

21 / 39 

+CPIN: SIM PIN 

PIN1 is required 

+CPIN: SIM PUK 

PUK1 is required 

Saves parameters in 
non-volatile memory 

AT&W 

OK 

The configuration settings are stored. 

 

3.2

 

CSD Connection   

3.2.1

 

Overview 

A Circuit-Switched Data Connection makes the wireless modem work in a manner similar to a regular analog modem.   
CSD (Circuit Switched Data) is the original form of data transmission developed for cellular systems. By using a single 
radio time slot, CSD is able to deliver 9.6 to 14.4 kbit/s data transmission to both the CELLULAR Network and PSTN 
Switching  Subsystem  through  direct  calls.  Most  of  the  time,  it  is  initiated  by  standard  AT  commands.  Using  the 
modem  to  access  remote  devices  by  CSD  is  often  more  convenient  than  installing  cables  and  data  lines.  Data 
collection and monitoring will be more flexible since CSD can be used for applications that are hard to wire or hard 
to access. 

Note

:  Ensure  that  your  SIM  card  has  the  CSD  Service  activated.  For  most  regions,  you  must  apply  to  your  mobile 

service provider to receive this service. 

 

3.2.2

 

Establishing a CSD Connection 

1.

 

Start SecureCRT with serial parameters 115200,8,n,1. 

2.

 

Type 

ATD <

phone number

and press 

Enter

 to establish a CSD connection. (e.g. ATD 123456, in which 123456 is 

the phone number.) 

3.

 

After remote side answering the CSD call, then the CSD connection has been established successfully. 

4.

 

To  close  the  CSD  connection,  type 

+++

.  The  modem  will  respond  with  OK  to  indicate  that  you  have  already 

switched back to the command mode. It means you can enter AT commands again via SecureCRT. 

5.

 

Type 

ATH

 and press 

Enter

 to disconnect. 

Содержание GoRugged M1000 UP

Страница 1: ...Robustel GoRugged M1000 UP Industrial Cellular USB Modem for 2G 3G 4G Networks User Guide Document Name User Guide Date 2015 10 07 Status Confidential Doc ID RT_UG_M1000 UP_v 1 1 1 www robustel com...

Страница 2: ...trade names mentioned in this document are the property of their respective holders Disclaimer No part of this document may be reproduced in any form without the written permission of the copyright o...

Страница 3: ...mputers office equipment home appliance etc An external antenna must be connected to the modem for proper operation Only uses approved antenna with the modem Please contact authorized distributor on f...

Страница 4: ...e modem Do not use the modem under extreme vibrating conditions Do not pull the antenna or power supply cable Attach detach by holding the connector Connect the modem only according to the instruction...

Страница 5: ...Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as the prod...

Страница 6: ...previous versions Release Date Firmware Version Doc Version Details 2014 01 17 1 0 0 V1 0 0 First Release 2014 05 13 1 0 0 V1 1 0 Update Section LED Indicator device pictures Safety Precautions Regul...

Страница 7: ...1 AT command Set 15 3 1 1 Install USB driver 15 3 1 2 Start SecureCRT 19 3 1 3 AT Command Examples 20 3 2 CSD Connection 21 3 2 1 Overview 21 3 2 2 Establishing a CSD Connection 21 3 2 3 Answering a...

Страница 8: ...formances of 3G and 4G high speed networks LTE downlink uplink up to 100 50 Mbps Antenna diversity for improved fringe performance optional Comprehensive SDK and enabling drivers for Linux and Windows...

Страница 9: ...items are missing or damaged Optional accessories can be purchased separately SMA antenna Stubby antenna or Magnet antenna optional The number of SMA antenna depend on the model of M1000 UP more deta...

Страница 10: ...of antenna interface 2G GSM 1 3G HSDPA 1 3G HSPA 2 4G LTE 2 USB Interface Number of Ports 1 x mini USB Female Speed USB 2 0 High Speed 480 Mbit s ESD Protection 15KV GPS optional for M1000 UP3P and M...

Страница 11: ...S EDGE GPRS LTE 800 900 1800 2100 2600 MHz DL UL up to 100 50 Mbps UMTS 900 2100 MHz GSM 900 1800 1900 MHz 25 to 60 C 5 to 95 RH M1000 UP3P HSPA UMTS EDGE GPRS UMTS 850 900 1900 2100 MHz DL UL 14 4 5...

Страница 12: ...us Description RUN Green On M1000 UP is powered up Off M1000 UP is powered off Status Green On The current network is connected Note only effective on 3G or 4G module if some 3G or 4G modules don t su...

Страница 13: ...eiving data you should use power input interface for power supply please check section 2 8 2 4 Install SIM Card Be sure to insert a SIM card before you use the modem Note A SIM card set with PIN code...

Страница 14: ...antenna is within correct frequency range as your GSM GPRS UMTS HSPA operator with impedance of 50ohm and connector is screwed tightly 2 6 Connect the Modem to External Device User can use the USB ca...

Страница 15: ...modem on a DIN rail with 3 pcs of M3 screws and then hang the DIN Rail on the holder You need to choose a standard holder 2 8 Power Supply The power supply range is 6 to 26 VDC Note Please take care...

Страница 16: ...can operate and configure M1000 UP via AT commands through mini USB port This chapter will introduce how to install USB driver and AT command examples while configuring M1000 UP 3 1 1 Install USB dri...

Страница 17: ...Robustel GoRugged M1000 UP User Guide RT_UG_M1000 UP_v 1 1 1 07 10 2015 16 39 2 Right click to enter Properties and then click Update Driver 3 Click Browse my computer for driver software...

Страница 18: ...RT_UG_M1000 UP_v 1 1 1 07 10 2015 17 39 4 Click Browse to locate to position of the USB driver you can find out relevant USB driver in the CD then click Next 5 After succeeding to install the USB driv...

Страница 19: ...t which binds to the USB interface of M1000 UP will open after USB driver has been installed Please check Device Manager Modems 7 Select the USB modem and right click to enter Properties In tab Modem...

Страница 20: ...1 2 Start SecureCRT We can enter AT commands to configure M1000 UP from serial software such as secureCRT you can download this software via link https app box com s arkn6xk1asgs1myvuuie 1 Double cli...

Страница 21: ...stry standard line oriented command language used to communicate with the modem Followings are examples of some AT commands Please refer to the AT command guide for a full description Description AT c...

Страница 22: ...access remote devices by CSD is often more convenient than installing cables and data lines Data collection and monitoring will be more flexible since CSD can be used for applications that are hard t...

Страница 23: ...to be replaced by the character E g you would type ATD 86123456 in which 86 is the country code 3 2 3 Answering a CSD Connection 1 When secureCRT displays the RING response type ATA and press Enter 2...

Страница 24: ...chnology offers the benefit of using SMS short message service as an easy way to communicate over the mobile network The following topics are covered in this chapter 1 Sending a Short Message 2 Readin...

Страница 25: ...Type AT CMGF 1 and then press Enter 2 Type AT CNMI 2 1 and then press Enter 3 When a short message is received the modem will show the storage number of the message after CMIT SM x where the x is the...

Страница 26: ...messages Note Refer to the Documentation and Software CD AT_Commands AT_Commands pdf for further detail commands information using SMS 3 4 Cellular Network Connection 3 4 1 Overview A cellular network...

Страница 27: ...ws and your Windows settings Following steps are basing on Windows 7 Change baudrate of modem 1 You can set baudrate of the simulated COM port to highest speed following the diagram below The highest...

Страница 28: ...You can select the maxumum port speed as 230400 in tab Modem Modem Diagnostics Follow these steps to verify that the modem is installed properly and has been activated 1 Click the Diagnostics tab and...

Страница 29: ...ses from the modem will be displayed Click OK to close the window Adding Windows DUN Follow these steps to add Windows Dial up Networking 1 In the Control Panel open Network and Sharing Center and the...

Страница 30: ...Robustel GoRugged M1000 UP User Guide RT_UG_M1000 UP_v 1 1 1 07 10 2015 29 39 click Next 3 Select the No create a new connection option and then click Next 4 Select the Dial up option...

Страница 31: ...same as Device Manager Modems XXX USB modem 6 Type 99 1 in the Phone number text input box and type the User name and Password in the appropriate text boxes and then click Connect Note User Name and...

Страница 32: ...d M1000 UP User Guide RT_UG_M1000 UP_v 1 1 1 07 10 2015 31 39 7 After dial up successfully it will show window below 8 Also you can try to ping to www google com to check whether GPRS connection has b...

Страница 33: ...Robustel GoRugged M1000 UP User Guide RT_UG_M1000 UP_v 1 1 1 07 10 2015 32 39...

Страница 34: ...ied by GSM 03 38 The corresponding ISO 8859 1 decimal codes are shown in the rightmost column Note that the euro sign is also included Hex Dec Character name Character ISO 8859 1 DEC 0 00 0 COMMERCIAL...

Страница 35: ...C 28 LATIN CAPITAL LETTER AE 198 0 1D 29 LATIN SMALL LETTER AE 230 0 1E 30 LATIN SMALL LETTER SHARP S German 223 0 1F 31 LATIN CAPITAL LETTER E WITH ACUTE 201 0 20 32 SPACE 32 0 21 33 EXCLAMATION MARK...

Страница 36: ...TIN CAPITAL LETTER L L 76 0 4D 77 LATIN CAPITAL LETTER M M 77 0 4E 78 LATIN CAPITAL LETTER N N 78 0 4F 79 LATIN CAPITAL LETTER O O 79 0 50 80 LATIN CAPITAL LETTER P P 80 0 51 81 LATIN CAPITAL LETTER Q...

Страница 37: ...114 0 73 115 LATIN SMALL LETTER S s 115 0 74 116 LATIN SMALL LETTER T t 116 0 75 117 LATIN SMALL LETTER U u 117 0 76 118 LATIN SMALL LETTER V v 118 0 77 119 LATIN SMALL LETTER W w 119 0 78 120 LATIN...

Страница 38: ...AT command e g ATD123456 No Carrier when trying to issue a data communication Is the SIM card configured for data fax calls Configure the SIM card for data fax calls Ask your network provider if nece...

Страница 39: ...rds Institute GND Ground GPRS General Package Radio Service GSM Global Standard for Mobile Communications IMEI International Mobile Equipment Identification kbps kbits per second LED Light Emitting Di...

Страница 40: ...sion A RF Connector SMS Short Message Service TCP IP Transmission Control Protocol Internet Protocol TE Terminal Equipment also referred to as DTE Tx Transmit Direction UART Universal Asynchronous Rec...