Warnings 

Installation, use and maintenance manual – Supercromo 

5

III

If you smell gas:

 

„

Do not use electrical devices such as telephones, 

multimeters or other equipment that may cause 

sparks next to the appliance.

 

„

Shut off the gas supply by turning the valve off.

 

„

Open immediately doors and windows to create a 

cross-current of air to ventilate the room.

 

„

Switch off the power supply via the external dis-

connect switch in the power supply electrical pan-

el.

 

„

Use a telephone away from the appliance to ask for 

intervention from qualified personnel.

Poisoning

 

„

Ensure the flue gas ducts are tight and compliant 

with the regulations in force.

 

„

Upon completing any procedure, ensure the tight-

ness of the components.

Moving parts

The appliance contains moving parts.

 

„

Do not remove guards during operation, and in 

any case prior to disconnecting the power supply.

Burn hazard

The appliance contains very hot parts.

 

„

Do not open the appliance and do not touch inter-

nal components before the appliance has cooled 

down.

 

„

Do not touch the flue gas exhaust before it has 

cooled down.

Electrocution hazard

 

„

Disconnect the electrical power supply before any 

operation on appliance components.

 

„

For electrical connections exclusively use compli-

ant components and according to the specifica-

tions provided by the manufacturer.

 

„

Ensure the appliance cannot be accidentally 

switched back on.

Earthing

Electrical safety depends on effective earthing sys-

tem, correctly connected to the appliance and in-

stalled according to the regulations in force.

Air flow

Do not obstruct the fan intake or the warm air 

outlet.

Distance from combustible or flammable mate-

rials

 

„

Do not deposit flammable materials (paper, dilu-

ents, paints, etc.) near the appliance.

 

„

Comply with current regulations.

Aggressive substances in the air

The air of the installation site must be free from ag-

gressive substances.

Switching the appliance off

Disconnecting the power supply while the appli-

ance is running may cause permanent damage to 

internal components.

 

„

Except in the event of danger, do not disconnect 

the power supply to switch off the appliance, but 

always and exclusively act through the provided 

control device.

In the event of failure

Operations on internal components and repairs 

may exclusively be carried out by a TAC, using only 

original spare parts.

 

„

In the event of failure of the appliance and/or 

breakage of any component, do not attempt to 

repair and/or restore and immediately contact the 

TAC.

Routine maintenance

Proper maintenance assures the efficiency and 

good operation of the appliance over time.

 

„

Maintenance must be performed according to the 

manufacturer's instructions (see Chapter 7 

p.  23) 

and in compliance with current regulations.

 

„

Appliance maintenance and repairs may only be 

entrusted to firms legally authorised to work on 

gas appliances and systems.

 

„

Enter into a maintenance contract with an author-

ised specialised firm for routine maintenance and 

for servicing in case of need.

 

„

Use only original parts.

Keep the Manual

This Installation, use and maintenance manual 

must always accompany the appliance and must 

be handed to the new owner or installer in the 

event of sale or removal.

III.2 

   COMPLIANCE

 

EU directives and standards

The Supercromo series gas-fired convectors are certified 

in accordance with European regulation GAR 426/2016/

EU and meet the essential requirements of the following 

Directives:

 

2016/426/EU "Gas Appliances Regulation" as amend-

ed and added.

 

2014/30/EC "Electromagnetic Compatibility Directive" 

as amended and added.

 

2014/35/EC "Low Voltage Directive" as amended and 

added.

Содержание Supercromo

Страница 1: ...Installation use and maintenance manual Supercromo Fired by natural gas LPG Independent gas fired convectors with direct exchange to heat small and medium sized rooms...

Страница 2: ...ered trademarks contained within this publication are not affected With the aim of continuously improving the quality of its products Robur S p A reserves the right to modify the data and contents of...

Страница 3: ...p 9 2 3 Appliance positioning p 10 2 4 Minimum clearance distances p 10 3 Heating engineer p 10 3 1 Warnings p 10 3 2 Supplied material p 10 3 3 Fuel gas supply p 10 3 4 Combustion products exhaust p...

Страница 4: ...al local regulations in force and the manu facturer s instructions provisions Misuse The appliance must only be used for the purpos es for which it has been designed Any other use is deemed hazardous...

Страница 5: ...s paints etc near the appliance Comply with current regulations Aggressive substances in the air The air of the installation site must be free from ag gressive substances Switching the appliance off D...

Страница 6: ...on products exhaust Fire safety and prevention Any other applicable law standard and regulation III 3 EXCLUSIONS OF LIABILITY AND WARRANTY Any contractual or extra contractual liability of the manufac...

Страница 7: ...operation of the gas fired convector very simple in itself is made completely automatic by the thermostatic regulation and the programmable timer standard in the 3002 model optional in the 3001 model...

Страница 8: ...and 3 Serial con nection of the coils terminals 2 and 4 F A Noise filter L Line M1 Limit thermostat M2 Fan thermostat M4 Control unit M9 2 A fuse N Neutral P1 Reset button RP7 Ignition electrode RP8 D...

Страница 9: ...C33 C63 residual head Pa 25 maximum equivalent length of coaxial exhaust duct m 1 sound power Lw max dB A 47 5 sound pressure Lp at 5 metres max dB A 28 5 Dimensions width mm 478 height mm 577 depth m...

Страница 10: ...ommended distance from the gas fired convector to the floor is 13 cm Figure 1 1 p 8 and possibly not more than 35 cm as higher heights would result in uneven heat distribution in the heated room Keep...

Страница 11: ...ce pipe union Perform connection in compliance with applicable regulations 3 3 3 Gas pipes sizing The gas pipes must not cause excessive pressure drops and consequently insufficient gas pressure for t...

Страница 12: ...ar Figure 1 1 p 8 3 4 2 Installation types The flue gas exhaust combustion air intake of the Supercromo gas fired convectors can be realised in one of the following ways With coaxial pipes with outlet...

Страница 13: ...installed with separate pipes suitable pipes and components available as optional must be used At the design stage it must be verified that the sum of the pressure drop of all components used does no...

Страница 14: ...r intake and flue gas exhaust pipes Do not damage or discard the cardboard jig with the drilling template required for installing the gas fired convector 3 Fix the jig to the wall where the gas fired...

Страница 15: ...e complete with heating body by loosening the fixing screws see Figure 3 7 p 15 and disconnect the casing earth cable 10 Fit the end of the flue gas exhaust pipe 35 mm onto the gas fired convector out...

Страница 16: ...not to work on live components Earthing The appliance must be connected to an effective earthing system installed in compliance with reg ulations in force It is forbidden to use gas pipes as earthing...

Страница 17: ...y Appliance defects or faults caused during transport or installation Gas smell Non compliant mains gas pressure Non compliant flue gas exhaust All situations that may involve operation abnormali ties...

Страница 18: ...e regula tor B by fully tightening its screw and adjusting the second stage regulator if necessary 6 When the adjustment is complete switch off the appliance After the adjustment stop and start the ap...

Страница 19: ...Reassemble the plug B 8 Turn on the gas fired convector and check the gas tightness of plug B 9 Check the gas pressure at the burner as described in Paragraph 5 2 1 p 17 10 Remove the LPG adhesive lab...

Страница 20: ...iance and the blower stops lighting up red signal light C The reset must be carried out manually using reset button A 8 Once the appliance is switched on turn knob B on the thermostat clockwise to inc...

Страница 21: ...n of the fan ther mostat by running the cables under the bracket 7 Use cable 93 black of the cable kit to connect the pro grammable timer terminals 2 and 4 to each other 8 Remove the room thermostat d...

Страница 22: ...wanted switching on and or switching off Pressing the TIMER button the on off programs set will be displayed Figure 6 4 15 combination of days in a week 1 From Monday to Sunday 2 Monday 3 Tuesday 4 We...

Страница 23: ...of gas fired con vector is the cleaning of the outer casing which must al ways be carried out with the appliance cold and without the use of solvents and the periodic removal of any dust that may accu...

Страница 24: ...odes is broken or badly posi tioned replace it or reposition it For a correct ignition the distance between the two ignition electrodes must be about 3 5 mm D The detection electrode is broken or badl...

Страница 25: ...ons possible room temperature control with presence detec on room temperature control with open window detec on with distance control op on with adap ve start control with working me limita on with e...

Страница 26: ...h presence detec on room temperature control with open window detec on with distance control op on with adap ve start control with working me limita on with electronic room temperature control plus we...

Страница 27: ......

Страница 28: ...on of safe environmentally friendly energy efficiency products through the commitment and caring of its employees and partners Robur S p A advanced technologies for air conditioning via Parigi 4 6 240...

Отзывы: