background image

  

Installation and operation manual – remote control 

13

 

Figure 12.2  

 Non resettable fault

13    TEMPERATURE  VALUES  DISPLAY

By pressing the 

 key several times, the remote control is able 

to display the values of the items shown in Table 13.1 

p. 13.

Table 13.1  

 Identification icon of the selected item

Selected item

Identification icon

set room temperature

DHW probe temperature*

delivery probe temperature

outdoor temperature*

* Not applicable to this model

 

Set room temperature display: corresponds to the set tem-

perature for the active temperature level (day/night/manu-

al) (Figure 13.1 

p. 13).

Figure 13.1  

 Set room temperature display

 

Delivery probe temperature display: corresponds to the 

temperature read by the delivery water probe in the boiler 

(Figure 13.2 

p. 13).

Figure 13.2  

 Delivery water probe temperature display

14    ROOM ANTIFREEZE FUNCTION

The remote control is equipped with the room antifreeze func-

tion (which can be excluded if necessary) which, regardless of 

the selected operating mode, controls the boiler activation 

when the temperature detected by the room probe is lower 

than the value set in parameter P01, thus providing protection 

of the system from the danger of freezing.

Содержание OCDS006

Страница 1: ...for Caldaria Remote control Installation and operation manual...

Страница 2: ...this publication are not affected With the aim of continuously improving the quality of its products Robur S p A reserves the right to modify the data and contents of this Installation and operation...

Страница 3: ...erature setting p 10 8 5 DHW temperature setting not applicable p 10 8 6 Outdoor probe Kd value setting not applicable p 10 9 Setting manual automatic operation p 10 9 1 Manual operation p 10 9 2 Auto...

Страница 4: ...ing to be made The remote control can be programmed with extreme ease a large LCD display makes this operation easier allowing you to check the settings you have made and to change them at any time Th...

Страница 5: ...lt requiring technical service Night level Day level 3 INSTALLATION For installation of the remote control on the Caldaria Plus refer to the Installation use and maintenance manual supplied with the C...

Страница 6: ...control 5 Fix the remote control to the fixing box by first inserting the upper part and pivoting on it until it is completely closed Figure 3 4 p 6 Figure 3 4 Closing the remote control 6 Power the...

Страница 7: ...save the value 8 To exit the configuration mode press Figure 4 2 Changing the selected value flashing The editable parameters are as follows P00 Room temperature probe correction Value to add subtrac...

Страница 8: ...press the knob within 10 seconds 4 The display shows the flashing number of the parame ter instead of the time and the value associated with the parameter instead of the temperature 5 Turn the knob to...

Страница 9: ...elected state Selected status Identification icon clock day temperature night temperature The value of the item is displayed in the lower left corner instead of the time together with the flashing of...

Страница 10: ...for models of the Caldaria family must be set to 80 C The change of this value will be operative on the boiler until the remote control is con nected to it 8 5 DHW TEMPERATURE SETTING NOT APPLICABLE 8...

Страница 11: ...entification icon of the heating program operation Function Identification icon heating program display PROG not flashing change heating program PROG flashing Once the changes have been made press the...

Страница 12: ...change made Figure 11 1 p 12 3 To deactivate the function before it expires press the key Figure 11 1 Temporary change of the room setpoint 12 FAULT SIGNALS Any faults are displayed by the remote con...

Страница 13: ...o the set tem perature for the active temperature level day night manu al Figure 13 1 p 13 Figure 13 1 Set room temperature display Delivery probe temperature display corresponds to the temperature re...

Страница 14: ...08 00 16 30 22 00 00 00 06 00 08 00 16 30 22 00 Saturday Sunday 00 00 07 00 23 00 00 00 07 00 23 00 How to reset default values 1 Set the remote control to the OFF mode 2 Press and hold down the and k...

Страница 15: ...for antifreeze function 0 0 C OFF 0 1 10 0 C Stop temperature for the room antifreeze function set value 0 6 C Heating time programming resolution 30 minutes Maximum number of daily on off 48 Number...

Страница 16: ...ingonia BG Italy 39 035 888111 F 39 035 884165 www robur it robur robur it Robur is dedicated to dynamic progression in research development and promotion of safe environmentally friendly energy effic...

Отзывы: