First start-up
Installation, use and maintenance manual – Next-R
39
5
Table
5.8
Nozzle data
R15
R20
R30
R40
R50
R60
R80
Installation data
Nozzle
Diameter (Ø)
G20
mm
5,80
6,00
7,80
8,80
9,30
10,40
10,30
Code
G20
-
202
209
203
205
204
219
228
Diameter (Ø)
G25
mm
5,80
6,00
7,80
8,80
9,30
11,60
Code
G25
-
202
209
203
205
204
220
Diameter (Ø)
G25.1
mm
6,65
6,80
9,50
12,30
- (1)
12,20
Code
G25.1
-
210
216
211
218
- (1)
223
Diameter (Ø)
G25.3
mm
5,80
6,00
7,80
8,80
9,30
11,40
Code
G25.3
-
202
209
203
205
204
221
Diameter (Ø)
G27
mm
6,65
6,80
9,50
12,30
- (1)
12,20
Code
G27
-
210
216
211
218
- (1)
223
Diameter (Ø)
G2.350
mm
6,65
6,80
9,50
12,30
- (1)
14,10
- (2)
Code
G2.350
-
210
216
211
218
- (1)
222
- (2)
Diameter (Ø)
G30
mm
3,85
4,20
5,10
5,60
5,75
7,60
Code
G30
-
214
215
212
217
213
225
Diameter (Ø)
G31
mm
3,85
4,20
5,10
5,60
5,75
8,10
Code
G31
-
214
215
212
217
213
224
Diameter (Ø)
LPG
mm
3,85
4,20
5,10
5,60
5,75
7,80
Code
LPG
-
214
215
212
217
213
241
(1)
Operation with this type of gas does not require the use of the nozzle.
(2)
The gas unit heater cannot operate with this type of gas.
5.3.1
R15/R20/R30/R40/R50
How to change gas (Figure 5.3
39)
1.
Cut o
ff
electric power and gas supply.
2.
Unscrew the hexagonal seal that connects the gas pipe (A)
to the nozzle holder
fi
tting. Take care not to lose or damage
the internal gasket (B) nor the o-ring (D).
3.
Move the gas pipe and pull out the nozzle (C), using a screw-
driver if necessary.
4.
Remove the gasket (B) and o-ring (D) from the old nozzle
and mount it on the new nozzle.
5.
Insert the new nozzle into its seat, checking the concordance
with Table 5.8
39. For the R50 gas unit heater only, and
only when fed with G25.1, G27 and G2.350 gas, the existing
nozzle must be removed.
6.
Reassemble the gas pipe, checking that the round gasket in
the seal is well positioned. Close the seal applying a torque
of 62±2 Nm.
7.
Adjust the appliance for the new gas type, adjusting the
burner pressure as described in Paragraph 5.2.1
35.
8.
Replace the sticker indicating the gas type on the appliance
with the sticker for the new gas type.
For the R15 model, in case of changeover from any type
of gas to LPG, G30 or G31, and vice versa, it is necessary to
replace also the component shown in Figure 5.4
with the one supplied with the gas change kit, indicated
by the letter A.
Figure
5.3
Gas changeover for gas unit heater
A
Gas supply pipe
B
Gasket
C
Nozzle
D
O-ring
E
Gas valve
A
B
C
E
D
Содержание Next-R
Страница 51: ......