background image

PRC Series 

Portable Room Cleaner

Owner’s Manual

Installation, Operation & Maintenance

Revised 04-30-2020

Содержание PRC Series

Страница 1: ...PRC Series Portable Room Cleaner Owner s Manual Installation Operation Maintenance Revised 04 30 2020 ...

Страница 2: ......

Страница 3: ...l Installation Operation Maintenance Manufactured by RoboVent 37900 Mound Road Sterling Heights MI 48310 USA 888 762 6836 www robovent com 2020 RoboVent Product Group Inc All rights reserved Models PRC 1200 1200 CFM PRC 800 800 CFM PRC 1200 PRC 800 ...

Страница 4: ...ructions Section 100 Page 5 Features of the PRC Series Section 200 Page 6 Receiving Inspection Section 300 Page 8 Installation Operation Section 400 Page 9 General Maintenance Procedures Section 500 Page 10 Troubleshooting Section 600 Page 11 Table of Contents ...

Страница 5: ...nd electrical components Any blockage of the air flow will decrease efficiency of this unit 4 Refer all service matters to qualified service personnel Servicing is required when the unit is damaged in any way including the control panel supply wiring or in the case of excessive filter loading 5 Disconnect power before working on the motor or blower wheel The motor or blower wheel should be disasse...

Страница 6: ...ontaminate the facility air system 4 Locking Wheels The RoboVent PRC comes standard with two stage locking caster wheels which lock the unit in all four directions Figure 2 5 Built In Acoustical Sound Plenum High Density Foam Barriers and Built In Acoustical Bass Traps have been engineered into the RoboVent PRC design to make it one of the quietest portables in today s market The RoboVent PRC s qu...

Страница 7: ...gure 3 9 A15 PleatLock Premium Cartridge Filter A15 PleatLock premium filter media is a proprietary cellulose polyester blend with an initial Minimum Efficiency Reporting Value of 15 MERV15 The base media is enhanced with a direct spray nanofiber to promote surface loading during operation and dust release during pulse cleaning Optional HEPA E11 95 Efficiency comparable to N95 Mask and HEPA H13 99...

Страница 8: ...den damage Again report any shortage or damage to the carrier and to your local RoboVent Representative The filter cartridges are typically shipped installed in your collector Be sure to check them for alignment as they may have shifted during transit If they have shifted it is possible that damage may have been done Remove all filter cartridges and inspect thoroughly Note Do not return any damage...

Страница 9: ...te a horizontal suction which diverts harmful particulate away from the operator The unit draws air through a secondary internal baffling design that causes separation and deposition of the larger heavier dust particles These particles are diverted to the dust storage device thus reducing the dust load to the filter cartridges Finer particles are collected on the surface of the filter cartridges b...

Страница 10: ...r clamps by pulling outwards on the two levers located on each side of the filter Figure 5 Slide the cartridge out the door and replace with a new RoboVent filter Figure 6 PRC 800 Replacing the filter cartridge is as easy as opening the top hatch door and removing the filter Be sure to clean all dust and debris from the filter plenum before replacing the cleaned or new filter cartridge Figure 7 Re...

Страница 11: ... Blower wheel could be out of balance If the blower wheel has gone out of balance there will be excessive vibration In this case please contact the RoboVent Technical Department at 1 888 ROBOVENT Little or no suction across intake Check the following 1 Cartridge filter is loaded Review the pulsing instructions in General Operation Section 400 With the air hooked up press the Solenoid Plunger 25 30...

Страница 12: ... 2020 RoboVent Improving Lives through Clean Air 37900 Mound Road Sterling Heights MI 48310 USA ROBOVENT COM 888 ROBOVENT ...

Отзывы: