This value limits operating temperature.
When the Present Temperature(146) that indicates internal
temperature of Dynamixel is greater than the Temperature
Limit(31), the Over Heating Error Bit(0x04) and Hardware Error
Bit(0x80) in the Hardware Error Status(70) will be set.
If Overheating Error Bit(0x04) is configured in the
Shutdown(63), Torque Enable(64) is cleared to ‘0’ and Torque
will be disabled.
For more details, please refer to the
section.
Unit
Value Range Description
About 1°
0 ~ 100
0 ~ 100°
Caution
Do not set the temperature lower/higher than the
default value. When the temperature alarm shutdown occurs, wait
20 minutes to cool the temperature before re-use. Keep using the
product when the temperature is high can cause severe damage.
2. 4. 13. Min/Max Voltage Limit(32, 34)
These values are maximum and minimum operating voltages.
When current input voltage acquired from Present Input
Voltage(144) exceeds the range of Max Voltage Limit(32) and
Min Voltage Limit(34), Voltage Range Error Bit(0x01) and
Hardware Error Bit(0x80) in the Hardware Error Status(70) are
set. If Input Voltage Error Bit(0x10) is configured in the
Shutdown(63), Torque Enable(64) is cleared to ‘0’ and Torque
is disabled. For more details, please refer to the
section.
Unit
Value Range Description
About 0.1V
95 ~ 160
9.5 ~ 16.0V
2. 4. 14. PWM Limit(36)
This value indicates maximum PWM output. Goal PWM(100)
can’t be configured with any values exceeding PWM Limit(36).
PWM Limit(36) is commonly used in all operating mode as an
output limit, therefore decreasing PWM output will result in
decreasing torque and velocity. For more details, please refer
to the Gain section of each operating modes.
Values
Description
0(0%) ~ 885(100%) 885 = 100[%] output
2. 4. 15. Current Limit(38)