111
MAINTENANCE INFORMATION
ENG
7.5. CONDENSATE DRAINAGE
1.
Close the tap (A) and check the level of condensation in the container (B).
2.
Unscrew, if necessary, the valve (C) to drain the condensation.
3.
Push the valve (C) upwards until all condensation is let out.
4.
Tighten the valve (C) again.
Masterplat PLUS
Masterplat PLUS TP3
Masterplat PLUS LP
7.6. AIR FILTER CLEANING
1.
Unscrew the container (B) with the specific wrench.
2.
Remove the filter, clean it with compressed air and wash it, if necessary, with petrol or trichloroethylene.
3.
Refit the filter and tighten the container (B).
Masterplat PLUS
Masterplat PLUS TP3
Masterplat PLUS LP
Содержание Masterplat FREEZER