![RoboLabs ROBOJETFLOSS Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/robolabs/robojetfloss/robojetfloss_operating-manual_1470881017.webp)
tm2627 Jan-20
17
To disassemble the spinning head:
1. Remove all sugar from the head, turning upside-down if necessary.
2. Detach floss head cover (10) by removing three flat-head screws (23).
3. If the cover is ‘glued’ to the sidewall, gently tap with the screwdriver handle in
order to loosen the parts.
Note that the cover is made from aluminum and can be damaged by excessive
tightening of the screws, by throwing, or by heavy impact.
4. Remove central wing nut (21), steel washer (20), plastic holding washer (19).
Then, using a 7mm nut driver or wrench, remove the nuts that are securing the
wire ends to the terminal posts (26). Remove the nuts, lock washers, terminal
ends and washers and you can then lift off the sidewall with heating element (9)
as one unit.
5. Wash the sidewall and heating element with very hot water in order to melt
the flossugar. When the bulk of the flossugar is removed, carefully separate the
heater coil from the sidewall to clean the areas where they contact one another.
DO NOT IMMERSE HEATING ELEMENT TERMINAL LEADS IN WATER AS THIS MAY CAUSE
FAILURE!
6. The sidewall and heating element must be dry before reinstalling.
ABRASIVE OR MECHANICAL CLEANING OF HEATING ELEMENT AND SIDEWALL IS PROHIBITED!
Re-assembly of the spinning head is done in the reverse order. Once
completed, turn on the motor and power to the heating coil for approximately 30
seconds in order to spin off any remaining moisture.