background image

 

Page 2 of 12 

conditions

.    If  necessary,  should  keep  the  equipment  working  in  the 

suitable  temperature  &  humidity  (within  the  restrained  scope).  We 
recommend operating unit in a dust free environment. 

3.

 

EDFA equipment can be powered by AC or steady DC voltage. In both of 

AC & DC, AC is the main power supply. 
Request of power supply: 

AC input   

94-245VAC, 50-60Hz 

DC input   

36-60VDC, (48V source recommended)   

Power consumption 

Maximum 50W 

4.

 

The DC power supply of the equipment must be the SELV supply type 

as stipulated in the CAN/CSA C22.2 No.950-95 standard. 

5.

 

Unit  should  have  good  grounding  with  grounding  resistance

4Ω

According to common international standards, AC plugs must be tri-wire with

 

the middle wire being the grounding wire. 

Before connecting power circuit, please use appropriate (#20AWG or more) 
electric wire to connect the grounding screw on the bottom to the grounding 
frame. When using DC input power supply, the equipment chassis must be 
grounded following the appropriate procedures for the respective location. 

 

2.3

 

Optical connectivity 

1.

 

Clean all fiber patch cords before connecting to the EDFA unit. 

Cleaning Guidelines: 

Fiber Patch cord connectors 

-  Remove  the  dust  cap  of  the  fiber  connectors  and  wipe  the  fiber 
connector tip with a dry lint-free cloth. Check if there are scratches or 
debris on the connector surface by using a microscope (ie.100x or 200x). 

- If no scratch or debris are found, the connector is ready for connection. 
If scratches or debris are found, repeat the fiber patch cord connector 
cleaning guidelines. 

Fiber Bulkhead connectors 

- Compressed air may be used to clean fiber bulkhead connectors. Use 
compressed air according to the following specifications (at least): 

- Non-residue, inert gas for precision dust removal 

- Ultra-filtered to < 0.2 microns 

- Recommended for optical systems 

- Using compressed air as listed above, remove the bulkhead dust 
cover and hold the can of compressed air about 6 inches away from 
the connector. After spraying a few short bursts into the bulkhead, 

Содержание EDFA-4429 Series

Страница 1: ...1 15 55 50 0n nm m C CA AT TV V E Er rb bi iu um m D Do op pe ed d F Fi ib be er r A Am mp pl li if fi ie er r E ED DF FA A 4 44 42 29 9 S Se er ri ie es s U US SE ER R M MA AN NU UA AL L Ver 2 0en ...

Страница 2: ...ectivity 2 3 0 EDFA CONTROLS INDICATORS AND ALARMS 4 3 1 Operation of the panel 4 4 0 PORT AND CABLE ASSIGNMENTS 6 4 1 Management Port RJ 45 7 4 2 RS232 Console port DB9 9 4 3 Power Connection 10 5 0 FAULT MESSAGES 10 5 1 Warning status 11 5 2 Alarm status 11 5 3 Fault troubleshooting 11 6 0 WARRANTY AND REPAIRING UNITS 12 ...

Страница 3: ...chassis total output power 1000mW offers maximum 16 optical outputs 2 0 INSTALLATION 2 1 Unpacking Please inspect the shipping boxes for any obvious damages Unpack the unit from all packaging boxes Inspect the appearance of the unit for any shipping damages Document and inform the shipping company and your local representative if any damage was found Save the shipping boxes and their inserts for f...

Страница 4: ...t power supply the equipment chassis must be grounded following the appropriate procedures for the respective location 2 3 Optical connectivity 1 Clean all fiber patch cords before connecting to the EDFA unit Cleaning Guidelines Fiber Patch cord connectors Remove the dust cap of the fiber connectors and wipe the fiber connector tip with a dry lint free cloth Check if there are scratches or debris ...

Страница 5: ... panel and disconnect each fiber connector from the bulkhead mounted on the plate Clean each fiber connector according to the fiber cleaning guidelines 2 Make sure the laser key switches on the front panel of the transmitter are in the OFF position 3 Connect the fiber patch cord from the output of the transmitter to the optical power meter 4 Turn the transmitter laser key switch to the ON position...

Страница 6: ...ct 48V power supply B Turn on power switch in the back panel Front panel displays KEY OFF Laser Status lamp is Red C Input power then press laser start up key switch Front panel shows KEY ON Laser status lamp turns green from red 3 1 2 Start up main menu Press buttons and the following menu will be displayed in a sequence cycle Menu 1 Model Read only menu tells the type of this equipment Menu 2 S ...

Страница 7: ...u tells the status of power1 Menu 12 Power2 Read only menu tells the status of power2 Menu 13 Unit Temp Read only menu tells the case temperature Menu 14 IP Adjustable list displays the IP address Menu 15 SUB Adjustable list displays the address of net mask Menu 16 GW Adjustable list displays the gateway address Menu 17 TR1 Adjustable list displays the TRAP1 address Menu 18 TR2 Adjustable list dis...

Страница 8: ...me time to select 5 this position then press button to change 5 to 6 and then press button at same time to save the modified IP is 192 168 000 016 3 LCD Contrast Level Set LCD Contrast Level Select this menu press the button at the same time to enter the modified status press the button to set the brightness of the LCD last press the button at the same time to save 4 Set Reset Settings menu Choose...

Страница 9: ...t such as other EDFA 4429 or network Hub Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 ohm Category 3 4 or 5 cable for 10 Mbps connections or 100 ohm Category 5e cable for 100 Mbps connections Please make sure that the cable length does not exceed 100 meters 305 feet 4 1 2 Pin assignment For network management connectivity RJ 45 connector in each side...

Страница 10: ...or MDI X of the EDFA 4429 series and any device with a standard network interface such as a work station or server or to a network interconnection device such as a bridge or router 1 Ensure that the device to be connected has a 10BASE T or 100BASE TX network interface card NIC 2 Prepare a twisted pair Ethernet cable with RJ 45 plugs on each end Use Cat 3 4 or 5 cable for standard 10Mbps Ethernet c...

Страница 11: ... 3u standard has more strict order for high speed Ethernet So when cascade device except for this EDFA 4429 series please follow the above connection regulation But please don t reckon in the EDFA 4429 series or connected cable related device in cascade length because EDFA 4429 series divide the connected path into unattached port 4 1 4 Connection Management Out Band Remote management can be perfo...

Страница 12: ...g of data 3 TXD transmitter data 5 SG signal Table 4 3 Pin information 4 3 Power Connection 4 3 1 Connection Description The power module provides stable operating power for the system to meet the power supply requirements of all the components in the system 5 0 FAULT MESSAGES EDFA 4429 series FTTP EDFA can monitor system operation and generate brief warning notes taking corrective actions regardi...

Страница 13: ...rn to their normal status and there is no need for user to interfere But what should emphasize is that the problem showed by alarm cannot be ignored because there may be some serious system faults Work status Status display LED color Explanation Present laser deflection is low Key Off Red The EDFA isn t working It s shut down Present case temp Red Warning when the temp 60 C Input Input Low Red Opt...

Страница 14: ...ide two years warranty for the product 2 The software CPU has the purpose of monitoring laser status digital display alarms and network management In case of red LED blinking Alarm please return the equipment for repairing User should not open the top cover for repairing opening the cover of the EDFA unit will void the warranty maintenance and material fees will be charged for repair if the unit h...

Отзывы: