  ELECTRICAL  CONNECTION

ELECTRICAL  REQUIREMENTS

Any permanent electrical installation must comply
with the latest I.E.E. Regulations and local Electricity
Board regulations. For your own safety this should be
undertaken by a qualified electrician  e.g. your local
Electricity Board, or a contractor who is on the roll of
the National Inspection Council for Electrical
Installation Contracting (NICEIC).

ELECTRICAL  CONNECTION

Before connecting to the mains supply ensure that
the mains voltage corresponds to the voltage on the
rating plate inside the cooker hood.

This appliance is fitted with a 2 core mains cable and
must be permanently connected to the electricity supply
via a double-pole switch having 3mm minimum contact
gap on each pole. A Switched Fuse Connection Unit
to  BS.1363  Part  4,  fitted  with  a  3  Amp  fuse,  is  a
recommended mains supply connection accessory to
ensure  compliance  with  the  Safety  Requirements
applicable to fixed wiring instructions.

The wires in this mains

lead are coloured in
accordance with the
following code:

Blue

Neutral

Brown

Live

As the colours of the wires
in the mains lead of this
appliance may not
correspond with the
coloured markings
identifying the terminals in
your connection unit,
proceed as follows:-

The wire which is coloured blue must be connected
to the terminal which is marked with the letter ‘N’ or
coloured black.

The wire which is coloured brown must be connected
to the terminal which is marked with the letter ‘L’ or
coloured red.

CH

Fiche de sécurité class 1, 250 V~ 10A
2 poles + terre.

Stecker der Schutzklasse 1, 250 V~ 10A
Zweipolig mit Schutzkontakt (Erde).

Spira di sicurezza classe 1, 250 V~ 10A
2 poli + terra

SEV 1011, SN416534-2, CH-Typ 12

Green & Yellow        Earth

Содержание Premium 2 610-910

Страница 1: ...Premium 2 610 910 FR GB Mode d emploi et installation Hotte de Cuisine Instructions for use and installation Cooker Hood...

Страница 2: ...NDEX RECOMMENDATIONS AND SUGGESTIONS 11 CHARACTERISTICS 12 INSTALLATION 14 USE 16 MAINTENANCE 17 GB FR Manuel d Instructions SOMMAIRE CONSEILS ET SUGGESTIONS 19 CARACTERISTIQUES 20 INSTALLATION 22 UTI...

Страница 3: ...than for which it has ben de signed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it doe...

Страница 4: ...ight Blower Filters 8 2 square fixing brackets 9 1 Flange 150 mm 20 3 Closing element Ref Q ty Installation Components 12a 8 Screws 4 x 16 12b 4 Screws M5 x 16 12c 3 Screws 3 5 x 9 5 Q ty Documentatio...

Страница 5: ...13 EN 258 263 270 30 599 45 50 5 288 552 298 150 108 0 170 610...

Страница 6: ...a u l t y h a n g i n g d u e t o t h e d r i l l i n g a n d t h e s e t t i n g u p o f p l u g s he ood can be tted onto the lo er surface of the all furniture 50 mm min from the surface of the co...

Страница 7: ...provi ded o remove the possible charcoal lte In the recirculation mode he ltered air is evacuated in itchen through an outlet placed on th e top of furniture or th e h ood o drill a hole of 155 mm on...

Страница 8: ...he motor t his f unction c an be de acti vated I ntensive s peed cannot b e a ctivated when the de lay function is on Intensive speed has been timed at 10 minutes H appears on the display and a spot d...

Страница 9: ...SE FILTERS The filters must be c leaned e very 2 months of ope ration or more frequently for particularly heavy usage Open the Comfort Panel by turning the knobs provided Open the panel Remove the fil...

Страница 10: ...moved as above A defective light is cutting off the second one s In this case you have to change the two lights REPLACING ACTIVATED CHARCOAL FILTERS These filters are not w ashable and cannot be rege...

Страница 11: ...usivement la hotte Ne pas laisser les flammes libres forte intensit quand la hotte est en ser vice Toujours r gler les flammes de mani re viter toute sortie lat rale de ces derni res par rapport au fo...

Страница 12: ...ip de Commandes Lumi re Groupe Ventilateur Filtres 8 9 1 Flasque 150 mm 20 3 Profil fermeture R f Q t Composants pour l installation 12a 8 Vis 4 x 16 12b 4 Vis M5 x 16 12c 3 Vis 3 5 x 9 5 Q t Document...

Страница 13: ...FR 21 610 258 263 270 30 599 45 50 5 288 552 298 150 108 0 170...

Страница 14: ...te peut tre install e directement sur la surface inf rieure des Armoires M urales 650 mm min depuis le Plan de Cuisson R aliser une ouverture pour l embo tage sur la surface inf rieure de l rmoire Mur...

Страница 15: ...iltres anti odeur au charbon actif L air filtr est vacu dans la pi ce travers une ouverture plac e sur la partie sup rieure du meuble ou de la h otte Percer un trou de 155 mm sur l ventuelle tablette...

Страница 16: ...dre le moteur La vitesse intensive ne peut pas tre actionn e si la fonction Delay est active La vitesse in tensive est temporis e sur 10 minutes sur l afficheur est vi sualis e l inscription H et le p...

Страница 17: ...u plus fr quemment en cas d emploi particuli rement intense Ouvrir le Confort Panel en intervenant su les boutons sp cia lement pr vus Retirer les filtres l un a pr s l autre en intervenant sur le s d...

Страница 18: ...nt sur les crochets pr vus cet effet Remonter les filtres anti graisse REMPLACEMENT LAMPES Retirer les 3 Vis qui fixent le Support clairage et ter ce d er nier de la Hotte Extraire la Lampe du Support...

Страница 19: ...uch tung 2 x 9 W 910 1 x 11 W 610 Orange Purple AZ UR AZ UR AZ UR BLAU BLACK NOIR SCH W ARZ BLUE BLEU BLAU BROW N BRUN BRAUN G REEN Y ELLOW VERT J AUNE G R N G ELB G REY G RIS G RAU LIG H T BLUE BLEU...

Страница 20: ...Connection Unit to BS 1363 Part 4 fitted with a 3 Amp fuse is a recommendedmains supply connectionaccessoryto ensure compliance with the Safety Requirements applicable to fixed wiring instructions Th...

Страница 21: ...A3 Filtre recyclage assembl Recycling filter...

Страница 22: ...A4 PREMIUM 910 SM 899 298 288 50 5 45 258 263 270 852 0 170 30 200...

Страница 23: ...A5 PREMIUM 610 SM 258 263 270 30 599 45 50 5 288 552 298 200 0 170...

Страница 24: ...L 1000 mm L 600 mm L A6 910 610 L 700 mm L 900 mm Premium Premium...

Страница 25: ...A S 25 Rue des Rosiers Sainte C cile B P 60056 50800 VILLEDIEU LES PO LES France T l 02 33 91 26 50 Fax 02 33 51 54 79 e mail com france roblin fr For outside France Tel 33 0 2 33 91 26 57 Fax 33 0 2...

Отзывы: