9
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 ins) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied with
the chimney hood.
IN THE EXTRACTION MODE :
1. Fit the noise-reduction tubes over the round outlets on top of the canopy while pressing down until
they snap into position and then fit the non-return backflow flaps onto the top of the noise-reduction
tubes as illustrated Fig. 10.
2. Connect the ducting 150mm ( 6ins) and secure the connections with appropriate clamping rings or
adhesive tape.
3. Make the electrical connections as described in the section titled ELECTRICAL.
IN THE REMOTE INSTALLATION MODE :
1. Connect the ducting 200 mm ( 8ins) onto the round outlets on the top of the canopy and onto the
round inlet of the motors at a distance and secure the connections with appropriate clamping rings
or adhesive tape.
2. Connect the earth connections onto the terminals marked with the earth symbol and clamp the con
-
nectors onto the motors housing as illustrated Fig. 11.
IN THE RECIRCULATION MODE :
1. Connect the ducting 150mm ( 6ins) between motors and the recirculation spigot as illustrated Fig. 12
and secure the connections with appropriate clamping rings or adhesive tape.
2. Before fitting the chimneys to the canopy make the electrical connections as described in the section
titled ELECTRICAL.
• FITTING THE CHIMNEY STACK
1. Fix both sides of the 2 upper chimney stacks as illustrated in Fig. 4 using the screws provided.
2. Check again vertical and parallelism of the two chimneys.
3. Pull on the two lower chimneys and secure them temporarily unscrewing a little bit the lower self
tapping screws as illustrated in Fig 13.
• FITTING THE CANOPY ONTO THE TWO CHIMNEYS
1. Place the canopy under the two chimneys and fix it with the eight CHC M5 screws provided as il
-
lustrated in Fig. 14.
2. Screw the lower self tapping screws of the two upper chimneys and fit the two lower chimney sections
by expending slightly them onto the canopy .
3. Connect the 6 ways connectors onto the right hand side of the two motors as illustrated in Fig. 7.
4. In the recirculation mode, remove the metal grease filters and insert the charcoal filters into the bases
of the 2 motor housing and secure the charcoal filters with the securing straps item A as illustrated in
fig. 15.
6. In the extraction mode fit the two deflectors as illustrated in Fig. 6.
5. Fit the metal grease filters.
GB
Содержание LINEAR 1500 CENTRALE
Страница 40: ......
Страница 41: ...1 2 3 5 6 4...
Страница 42: ...7 9 11 12 10 8 770 820 870 920 970...
Страница 43: ...13 14 15 A...
Страница 44: ...16 2 LR03 AAA 1 5V 1 250 205 12 210 220 4 5 650 200 R 2 0 762 272 250 210 GABARIT POSE...
Страница 47: ...45 288 650 1498 324 324 500 56 65 164 164 58 5 442 nim 079 xam 077 911 961 500 150 150 53 463 inim 056...
Страница 48: ...46 A B C D E F F...
Страница 49: ...47 G H I J K L...