50mm MINIMUM
GREENHOUSE TYPE
OVER ALL WIDTH 'W'
BRICKWORK
RETURN
DIMENSION 'X'
REGENT (6 WIDTH)
1960mm
650mm
ROYALE (8 WIDTH)
2580mm
650mm
ROSETTE (10 WIDTH)
3210mm
965mm
REGAL (12 WIDTH)
3820mm
1270mm
RENOWN (14 WIDTH)
4450mm
1585mm
OVER ALL LENGTH 'L' = BASIC GREENHOUSE LENGTH
+ EXTENSION IF REQUIRED
BASIC
GREENHOUSE
LENGTH
GREENHOUSE EXTENSION
LENGTH
6 LONG
1990mm
6ft EXT LONG
1860mm
8 LONG
2610mm
8ft EXT LONG
2480mm
10 LONG
3230mm
10ft EXT LONG
3100mm
12 LONG
3850mm
12ft EXT LONG
3720mm
BRICKW
ORK
RETURN
DIMENSION
'X'
DOORWAY OPEN
ING
SINGLE = 660mm
DOUBLE = 1280mm
THIS PLAN APPLIES TO GREENHOUSES WITH DOORS AT ONE END ONLY.
DOUBLE BRICK SKIN
OPTION
Property of 'Robinsons Greenhouses'
TITLE:
© 2015
600
600
GUIDANCE NOTE FOR ROBINS
ONS DWARF WALL GREENHOUSES.
F
OOT
INGS
CONCRETE STRIP FOOTINGS SH
OULD BE A MINIMUM OF 400mm
WIDE X 200mm DEEP. IF THE SITE IS ON MADE UP GROUND IT IS
IMPORTANT THAT THE FOOTINGS ARE CUT INTO THE COMPACTED
GROUND BELOW.
WHERE THE GROUND IS LIABLE TO MOVEMENT SUCH AS HEAVY
CLAY OR LOOSE SANDY SOIL REINFORCING SHOULD BE ADDED
TO THE CONCRETE FOOTINGS.
W
A
LLS
IT IS MOST IMPORTANT THAT TH
E BRICKWORK IS IN ACCORDANCE
WITH THE DIMENSIONS PROVIDED AND IS SQUARE, LEVEL AND
UPRIGHT, THE DIAGONAL MEASUREMENTS SHOULD BE EQUAL.
WALLS CAN BE EITHER DOUBLE OR SINGLE SKIN.
THE TOP COURSE OF BRICKS SHOU
LD BE LAID FROG DOWN. IF
ENGINEERING BRICKS ARE USED
FOR THE TOP COURSE PLEASE
ENSURE THEY ARE SOLID NOT CE
LLULAR (WITH HOLES THROUGH
THEM) OR FIXING DOWN OF THE GREENHOUSE WILL BE A
PROBLEM. BRICKS SHOULD BE A
GOOD QUALIT
Y ST
OCK BRICK,
SAND FACED FLETTON TYPE BRICKS ARE NOT SUITABLE.
GABL
E DOOR OPENING
THE DOOR THRESHOLD REQUIRES BRICK WORK ACROSS THE
OPENING WHICH SHOULD BE LEVEL
WITH THE FINISHED FLOOR
LEVEL (F.F.L) OF THE GREENHOUSE.
THE OPENING FOR THE DOORWAY AND THE HEIGHT TO THE TOP
OF THE WALL FROM THE THRESHOLD LEVEL REQUIRE THE
HIGHEST ACCURACY AND ARE MOST IMPORTANT SO THAT THE
DOOR FITS THE APERTURE CORRECTLY. IT IS ADVISABLE TO MAKE
A WOODEN TEMPLATE TO CHECK THE DOOR APERTURE DIMs.
IF SINGLE SKIN WALLS ARE USED THEN PIERS SHOULD BE FORMED
AT THE DOOR OPENING.
IN ORDER TO SUPPORT THE OUTER EDGE OF THE DOOR
THRESHOLD THERE MUST BE A PR
OJECT
ION OF
BRICKWORK /
CONCRETE INFRONT OF THE DOOR END WALLWITH A MINIMUM
WIDTH OF 50mm. THIS NEEDS TO BE LEVEL WITH
THE DOOR THRESHOLD OPENING.
GREENHOUSE
DWARF WALL PLAN
BRICKW
ORK
RETURN
DIME
NSIO
N
'X'
O
V
ER A
LL
L
EN
G
TH
'L
'
OV
ER ALL
WIDTH 'W'
SING
LE BRICK SKIN
OPTION
WITH DOUBLE PIERS
Содержание Renown Dwarf
Страница 9: ...9 D604 TRANSIT BOLT ON DIAGONALS 15mm D604 15mm D609 10mm D609...
Страница 11: ...11 D608 D174 D675 D741L D600 D675 D723 D653 D111 D742R D741L D741L D608 D626 D110 D626 D656 D723...
Страница 13: ...13 D655 D741L D670 D111 D742R D741L D741L D608 D626 D743 D608 D740 D174 D626 D656 D740...
Страница 14: ...14 EQUAL...
Страница 17: ...17 D862 D862 D863L 2 2 2 2 2 FLIP VIEW D119 CUT 6mm SILICONE...
Страница 19: ...19 D889 GLASS D889 GLASS D1208 GLASS...
Страница 24: ...24 D220 D220...
Страница 25: ...25 D079 D862...
Страница 27: ...27 D085 D865 D086 15 7 N A 7 D150 15 4 N A 4 D865 D845 D733...
Страница 28: ...28 D861 1 D088 1 Part No Q D861 D088 D861 D088...
Страница 30: ...30 O7mm...
Страница 37: ...37...