5.3
SHELF HEIGHT AND SIDE CLEARANCES
The fire may be fitted beneath a shelf.
5.3.1 COMBUSTIBLE SHELF
A shelf may be fitted above the heater provided that it complies with
the dimensions shown in the diagram.
No combustible shelf may be fitted below the minimum of 150mm.
The minimum clearance to combustible sides must comply with the
dimensions in the diagram.
A minimum clearance to adjacent combustible walls, of 500mm,
is required from the side of the fire.
5.3.2 NON-COMBUSTIBLE SHELF
The underside of a non-combustible shelf not more than 75mm deep
must be at least 25mm above the top of the fire. This clearance is
necessary for outer case removal. For deeper shelves, allow 13mm in
shelf height for every 25mm increase in depth.
SIDE CLEARANCES:
A clearance of at least 25mm must be left on either side of the fire to
facilitate removal of the outer case during servicing.
FIRE SURROUND:
The fire is suitable for purpose-made proprietary hearths/surrounds
o
with temperature rating of 150 C.
12
12
6.0 INSTALLATION OF FIRE
Fig 10.
6.1
UNPACKING
The fire is packed with the rear brick board already fitted in position. When unpacking refer to the check list to ensure that all of the
†
components are present and undamaged. Remove the top fitment from the carton. Remove the screw pack and spigot . Lift the carton
†
surround clear of the fire. The closure plate is packed inside the inner sleeve. Remove the coal pack. Remove the trim from the fire, by
lifting it upwards. The top of the trim is hooked over the top of the firebox and is held in place at the bottom by magnets. Lift the fire clear of
the bottom fitment of the carton.
Pack Contents: -
(i)
1
Fire Assembly
(ii)
1
Coal Pack
(iii)
1
Screw Pack
†
(iv)
1
Spigot
†
(v)
1
Closure Plate
(vi)
1
Installation Instruction Booklet
(vii) 1
User Instruction Booklet
†
= where supplied
6.2
PREPARATION OF FIRE
6.2.1 SPIGOT RESTRICTOR
The spigot restrictor is supplied in the screw pack and should be fitted only in the case of installation to a brick chimney, 178mm
diameter stone/lined flue of at least 3 metres effective height, with good draught.
DO NOT
fit the spigot restrictor if installation is to a
PRE-CAST FLUE
or a
METAL FLUE BOX / 5 INCH FLUE
.
Fit the restrictor with two of the self tapping screws supplied in the screw pack as shown in Fig 10.
2 SPIGOT
RESTRICTOR
FIXING SCREWS
depth 250mm
depth 200mm
depth 150mm
15
0mm
20
0mm
2
50
m
m
Top of Fire
COMBUSTIBLE SHELF
CLEARANCES
COMBUSTIBLE SIDES
CLEARANCES
200mm
MIN
M
A
X
20
0mm
sid
e
of
fir
e
M
AX
10
0m
m
100mm
MIN