3
Installation
Preparation
Ensure that the rangehood is not connected to the power supply until after installation is complete.
If you have an outlet leading outside, you can connect your rangehood, according to the image below, by means of
an extraction duct (enamel, aluminium, flexible pipe or inflammable material) with an interior diameter of 120mm.
The rangehood must be placed at least 65cm above the cooking surface. For best effect, do not install the
rangehood more than 75cm above the cooking surface.
Air Ventilation Setting
The rangehood can be set to one of two different ventilation settings: recycling or exhaust.
Outdoor Exhaust
This mode vents the extracted air outside. To set it, turn the adjuster to the outdoor position and install the
extraction duct.
Recycling
This mode filters the air through the carbon filters. To set it, turn the adjuster to the indoor position and install the
outlet cover.
Note
: the extensible pipe is an optional accessory and is not supplied.
Take off the protective film before installation.