Pre-Installation

 - continued

 

Ducting Options 

The method of ducting should be carefully considered before installing the rangehood.  The guide below 
recommends the ducting components to use for all common ducting configurations - through the top of the home 
(for the roof and soffit) and through the rear of the home.  150mm round ducting should be used in conjunction 
with this model rangehood.  Alternatively this rangehood can be operated in recirculation mode (see Recirculation 
mode pg 6).  

 

The highlighted area in the table below gives the recommended Uniduct item numbers for different 
mounting and outlet options.  

 

 

Duct mounting option

 

 

Rear 

 
 
 

 

 
 

 

Top (roof) 

 

 

 

 

Top (soffit/eave) 

 

 

 
 
 

 

 

Uniduct item numbers

 

150mm      

diameter round outlet 

1688 

1634 and                            

1635 

1634 and                         

1688 

                                                          

                                                                              

 

Extra lengths and/or bends may be required, depending on the length required and whether there is any 
structural material in the run e.g. rafters. 

 

Please note that this chart is designed as a guide.  Please consult Robinhood customer services if unsure. 

For NZ phone 0800 760 667 or www.robinhood.co.nz.  For AUS phone 1800 648 556 or www.robinhood.com.au.  

 

 

 

 

 

 

 

 

Содержание RWE3CH6SS

Страница 1: ...1 Description ROBINHOOD WALL CANOPY Model Numbers RWE3CH6SS RWE3CH9SS Model pictured RWE3CH9SS RWE Issue B All dimensions in mm Model may vary slightly from images pictured ...

Страница 2: ...e within 1500mm of the power cord exit from the rangehood o The power socket must be accessible and enable the end user to isolate the rangehood from the power for the purpose of internal cleaning or maintenance o 150mm round ducting adapter is supplied All other ducting accessories are not supplied All ducting must comply with local requirements and building codes o If re circulating ensure that ...

Страница 3: ...ation mode see Recirculation mode pg 6 The highlighted area in the table below gives the recommended Uniduct item numbers for different mounting and outlet options Duct mounting option Rear Top roof Top soffit eave Uniduct item numbers 150mm diameter round outlet 1688 1634 and 1635 1634 and 1688 Extra lengths and or bends may be required depending on the length required and whether there is any st...

Страница 4: ...ht for installation is 750mm above the hob Should you wish to have the unit lower or you have a ceiling higher than the typical 2 4 meter 8 foot then please choose the desired chimney extension kit from page 8 Minimum height from the hob surface to the underside face of the rangehood 600mm electric hob chimney extension kit required see page 8 650mm gas hob chimney extension kit required see page ...

Страница 5: ...e wall fixings check with a spirit level to ensure bracket is level Tighten screws 2 Mark the position of the decorative chimney at the ceiling and wall Cut the cornice moulding away if required to enable the chimney to sit flush against the wall and ceiling If a chimney extension kit is required see page 8 Chimney extensions 3 Only if ducting Mark and check then cut out the hole in the ceiling wa...

Страница 6: ...y pieces onto the canopy top Extend the upper chimney to the ceiling and secure in place with the top chimney bracket using two screws supplied Recirculation mode 1 This unit can be installed to operate in recirculation mode where ducting is not a chosen desired or practical option There are recirculation grilles fitted on each side of the upper chimney which allow the cleansed air to return to th...

Страница 7: ...ehoods fitted with charcoal filters are designed to remove grease and odours from cooking vapours prior to the cleansed air re entering the kitchen when the rangehood is in recirculation mode Charcoal filters should be replaced every two to four months depending on use Note Fully saturated charcoal filters can become a barrier to air movement therefore limiting rangehood performance In the event o...

Страница 8: ...8 Note When the maximum chimney height is to be used there will be a minimum of 25mm overlap required for top and bottom chimney assembly Chimney extensions ...

Страница 9: ...liances burning gas or other fuels You must read the details concerning the method and frequency of cleaning There is a fire risk if cleaning is not carried out in accordance with the instructions Do not flambé under the rangehood Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels The minimum distance between the h...

Страница 10: ...andling the product including the impact caused by objects scraped along thrown or dropped on the product surface or excessive weight being placed on the product Structural or support changes in or affecting the building or the application where the product has been installed Failure to clean or maintain the product as recommended or any other causes specified in the product information as being e...

Страница 11: ...ght being placed on the product Structural or support changes in or affecting the building or the application where the product has been installed Failure to clean or maintain the product as recommended or any other causes specified in the product information as being excluded from this warranty 3 Variations with the colour or gloss within the product or any ageing or fading of colour shine or glo...

Отзывы: