30
-->Wireless State).
To unlink the fixture from DMX transmitter.
The fixture can be unlinked from receiver via the menu item “ Unlink Wireless Adapter“ (Information--> Wireless
State --> Unlink Wireless Adapter.).
10. Error and information messages
Occurred errors during fixture operation are signalled by the yellow warning icon at the bottom line of the
screen:
Touch the warning icon or press the [ESCAPE] button to display error messages.
List of error and information messages:
Active Lamp Timer
This message appears if you try to switch on the lamp within 5 minutes after having switched it off. The fixture will
store the attempt to ignite the lamp and automatically ignites the lamp when the 5 minutes period will expire.
Lamp Error
If the ignition of the lamp is 4 times unsuccessful (the “Active Lamp Timer” message appeared 3 times before),
the display shows “Lamp Error”, meaning that the lamp could be damaged or even missed or there could be a
failure on the igniter or ballast.
Overheated
This message informs that the fixture head has been overheated and the lamp was switched off by means of
the head temperature sensor.
Base Overheated
This message informs that the fixture base has been overheated and the lamp was switched off by means of
the lamp driver temperature sensor in the base.
Lamp is too hot
The message will appear on the display if the lamp doesn’t ignite within 5 seconds.
Temper.Sensor Error
The message informs you that the communication betwen the head temperature sensor and the main proces-
sor failed and the lamp has been switched off.
Tilt Error 1
(Tilt Error 2)
This message will appear after the reset of the fixture if the head´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head is not
located in the default position after the reset.
Pan Error 1
(Pan Error 2)
This message will appear after the reset of the fixture if the yoke´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The yoke is not
located in the default position after the reset of the fixture.
Colour Wheel Error 1(Colour Wheel Error 2
)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default posi-
tion.
Cyan Lamella Error 1 (Cyan Error 2 )
The messages will appear after the reset of the cyan flag if the flag is not located in the default position.
Magenta Lamella Error 1 (Magenta Error 2 )
The messages will appear after the reset of the magenta flags if the flag is not located in the default position.
Yellow Lamella Error 1 (Yellow Error 2 )
The messages will appear after the reset of the yellow flags if the flag is not located in the default position.