- 47 -
CONTROL PANEL
CONTROL BOX
M4
M6
7-4-8.CONTROL.BOX.ASSY
Refer to Section 7-5 for disassembly, checking and reassembly procedures of the control panel .
(1) Put the cover onto the frame temporary .
NOTE : Don't set bolt for the control box.
(2) Pass wires drawn out generator and engine
to the control box .
(3) Connect the wires coming from the control
panel with wires coming from generator and
engine .
NOTE : Connect the wires of the same color.
(4) Install the control panel onto the control box .
(5) Mount the control panel together with the
control box (Control box Assembly) onto the
frame .
M4 × 12 mm Screw . . . 4 pcs .
M6 × 12 mm Screw . . . 4 pcs .
Tightening.torque.:...5.0-6.0. N•m.
.50-60.
kgf•cm.
.(3.7-4.8. ft•lbs)
Tightening.torque.:...5.0-6.0. N•m.
.50-60.
kgf•cm.
.(3.7-4.8. ft•lbs)
Содержание RGX7100
Страница 1: ...SERVICE MANUAL RGX7100 7800 GENERATORS Models PUB GS6828 Rev 07 09 ...
Страница 4: ......
Страница 6: ... 2 2 PERFORMANCE CURVES RGX7100 50Hz 220V 50Hz 240V N A N A ...
Страница 8: ... 4 RGX7800 50Hz 220V 50Hz 240V N A N A ...
Страница 59: ......
Страница 60: ...PRINTED IN THE USA ...