- 25 -
3) Check the wiring through ZCT on the IDLE
CONTROL UNIT .
Make sure that an output wire from main
coil is passing through the ZCT on the IDLE
CONTROL UNIT .
4) Checking the IDLE CONTROL UNIT Check
the resistance between five leads of IDLE
CONTROL UNIT with circuit tester .
IDEL CONTROL UNIT
OUTPUT WIRE
ZCT
CIRCUIT TESTER
(Resistance)
2
1
3
5
4
Terminal number of
the IDEL CONTROL UNIT
Circuit.tester..
(with.battery.power.source.1.5.V)
Apply.black.
⊖
.needle.of.the.circuit.tester
①
②
③
④
⑤
Apply.red.
⊕
.needle.
of.the.circuit.tester
①
-
∞
250kΩ
250kΩ
75kΩ
②
∞
-
∞
∞
∞
③
250kΩ
∞
-
250kΩ
75kΩ
④
250kΩ
∞
250kΩ
-
75kΩ
⑤
8 .5kΩ
∞
7 .8kΩ
7 .8kΩ
-
NOTE : The resistance readings vary depending on the types of circuit testers. The above
table shows an example of the resistance readings measured by an ordina,y analogue
circuit tester with I . 5 volt battery power source. It is advisable for you to check the
resistance readings using your standard circuit tester and revise the checking table.