- 18 -
Step
Parts to remove
Remarks and procedures
Fasteners
16
Electric starter (option)
Control box,
Diode recti
fi
er,
Magnetic switch
(1) Disconnect the grounding cable from battery.
(2) Disconnect the wire leading from the key switch
“ST” terminal to the magnetic switch.
(3) Disconnect the wire that connects the positive
terminal of the battery to the magnetic switch.
(4) Remove the electric starter.
12 mm box spanner
M8 nuts
12 mm box spanner
ELECTRIC STARTER
(option)
STEP 16
M8 x 28 BOLT : 2 pcs.
M8 NUT : 1 pc.