background image

13. Install two AA ENERGIZER brand batteries or equivalent into battery

compartment. Be sure to match positive (+) ends of batteries with
positive (+) battery terminals in the battery compartment. The display
will show as follows:

14. Replace cover on thermostat by snapping into place.

15. Turn on power to system. Test thermostat as described in the 

section 

To Test Thermostat

.

Programming Guide

Set Time of Day, Day of Week,
Temperature Differential

1. Press and hold SET.  Press PROG/MAN.

Release simultaneously.

Press

or

to change

time of day.

2. Press

Press

to change 

day of week

5

>

>

PROG

MAN

SET PROG/MAN

COOL-OFF-HEAT

AUTO - ON

SET PROG/MAN

>

>

SET P

>

>

1=MO
2=TU
3=WE
4=TH
5=FR
6=SA
7=SU

Содержание 110-653C

Страница 1: ...low voltage thermostat Do not install on voltages higher than 30V AC All wiring must conform to local and national building and electrical codes and ordinances Do not short jumper across terminals on the gas valve or at the system control to test installation This will damage the thermostat and void the warranty 110 653C 5 2 Day Programmable 1 Heat 1 Cool W A R R A N T Y I N T E G R A T E D C O M ...

Страница 2: ...ling system 2 Remove cover of old thermostat to expose wires Do not disconnect wires See Figure 1 3 Label wires per Table 1 Table 1 Old Label New Label Description M 4 RH R5 or R RH Heat Transformer hot side V or RC RC Cooling Transformer hot side Y or Y6 Y Cooling control H W or 4 W Heating control F or G G Fan control relay C Y or None Either cooling control or common side of trans former NOTE O...

Страница 3: ...CES WILL AFFECT THERMOSTAT OPERATION 1 Turn power off to the heating and cooling systems 2 Place COOL OFF HEAT in OFF position 3 Place AUTO ON switch into AUTO position 4 Remove the cover using a coin or screwdriver Figure 2 5 Place thermostat against the wall at desired location Make sure wires will feed through opening on base of thermostat 6 Mark placement of mounting holes see Figure 3 Set bas...

Страница 4: ...agrams on other side of this sheet Make sure wire connections are secure 12 Place fan option switch into either the ELEC or GAS position depend ing on the type of furnace Refer to Figure 5 Figure 5 4 PROG MAN CHANGE SET AUTO MAN Elec Gas RH AM PM MORN DAY EVE NITE RC W Y G FAN AUTO ON MOUNTING HOLES COOL OFF HEAT PROG MAN CHANGE SET AUTO MAN Elec Gas RH AM PM MORN DAY EVE NITE RC W Y G FAN AUTO ON...

Страница 5: ... cover on thermostat by snapping into place 15 Turn on power to system Test thermostat as described in the section To Test Thermostat Programming Guide Set Time of Day Day of Week Temperature Differential 1 Press and hold SET Press PROG MAN Release simultaneously Press or to change time of day 2 Press Press to change day of week 5 PROG MAN SET PROG MAN COOL OFF HEAT AUTO ON SET PROG MAN SET P 1 MO...

Страница 6: ...ATURE SETTING THE SYSTEM WILL TURN ON IF THE SYSTEM TURNS ON TOO OFTEN INCREASE THE TEMPERATURE DIFFERENTIAL Changing Fahrenheit F to Celsius C Press and hold SET Press Release both simultaneously Setting Daily Programming 1 Place COOL OFF HEAT switch in COOL position 2 Press SET 3 Press or to change MORN time 6 SET P SET P PROG MAN SET PROG MAN COOL OFF HEAT AUTO ON COOL OFF HEAT SET PR ...

Страница 7: ...TE for weekday opera tion and two settings MORN and NITE for weekend operation Adjust the program at any time by following the steps as outlined above Begin Programmed Operation 1 Place AUTO ON switch into AUTO 2 Place COOL OFF HEAT switch into COOL or HEAT depending on the season 3 Press PROG MAN button until indicator is in PROG position 7 PROG MAN SET PROG MAN COOL OFF HEAT AUTO ON SET PR COOL ...

Страница 8: ...cator is in MAN position 2 Press or to adjust temperature settings Reset To reset the thermostat to factory preprogrammed conditions press the RESET button located directly to the right of the display 8 PROG MAN SET PROG MAN COOL OFF HEAT AUTO ON PROG MAN SET PROG MAN COOL OFF HEAT AUTO ON T PROG MAN PROG MAN PROG MAN CHANGE SET AUTO MAN Elec Gas RH AM PM MORN DAY EVE NITE RC W Y G FAN AUTO ON RES...

Страница 9: ...IR CONDITIONING WILL RESULT IN A 5 MINUTE DELAY IN COMPRESSOR ACTIVATION 3 Put the COOL OFF HEAT switch into the OFF position The air conditioning system should turn off The fan may continue to run for a short period of time 4 Put the COOL OFF HEAT switch into the HEAT position 5 Press the button until the temperature setting is at least 3 degrees above room temperature The heating system should t...

Страница 10: ...e INSTALLATION Time shown on display is not the Change time of day setting current time of day See PROGRAMMING Thermostat does not Thermostat in MANUAL mode follow program See PROGRAMMING Thermostat may not have been programmed in HEAT or COOL position Verify program Check AM PM indicators at time of day and programmed time changes See PROGRAMMING Verify program and day of week are correct See PRO...

Страница 11: ...ating Control Heating Control Transformer 24 VAC 24 VAC 24 VAC 120 VAC Hot 120 VAC Hot 120 VAC HEAT COOL 4 WIRE SINGLE TRANSFORMER HEAT ONLY 2 WIRE SINGLE TRANSFORMER HEAT ONLY 3 WIRE SINGLE TRANSFORMER Factory Installed jumper Factory Installed jumper T H E R M O S T A T RH RC W Y G Hot Cooling Control Fan Control Transformer 24 VAC 120 VAC COOL ONLY 3 WIRE SINGLE TRANSFORMER HEAT COOL 5 WIRE TWO...

Страница 12: ...r reinstallation is not the responsibility of Maple Chase Company Repair or replacement as provided under this warranty is the exclusive remedy of the consumer Maple Chase Company shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product or under any other theory of liability Except to the extent prohibited by applicable law any i...

Отзывы: