background image

Technical Data

Power Requirements

120 VAC, 60 Hz, 

. . . . . . . . . . . . . 

1 Phase, 15 AMP minimum

Pressure Operating Range

0–3000 psi 

. . . . . . . . . . . . . 

(0 – 210 bar)

Maximum Delivery

0.28 GPM (1.1 liter/min)

. . . . . . . . . . 

Power Cord

No. 16 AWG, 3 wire, 

. . . . . . . . . . . . . . . . . . 

8.5 feet (2.6 m) long

Inlet Strainer

16 mesh

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Fluid Outlet Nipple

1/4 npsm (m)

. . . . . . . . . . . . . . . . . . . . 

Weight – without hose and gun

33 lb (14.8 Kg)

. . . . . . . 

Dimensions

Height: 20 inch (508 mm)

. . . . . . . . . . . . . . . 

Width: 17.5 inch (444.5 mm)

Depth: 17.5 inch (444.5 mm)

Wetted Parts

Stainless Steel, Zinc-Plated Steel, 

. . . . . 

Carbide, Aluminum, Nylon, Delrin

r

, Monel

 

Delrin

r

 is a registered trademark of the DuPont Company

Ordering and 

Technical Assistance

TO PLACE AN ORDER

, contact your Graco distrib-

utor, or call this number to identify the distributor
closest to you: 

1–800–367–4023 Toll Free

FOR TECHNICAL ASSIST

ANCE,

 service repair

information or assistance regarding the application of
Graco equipment: 

1–800–543–0339 Toll Free

The Graco Warranty and Disclaimers

WARRANTY

Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on
the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this
warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defec-
tive, with the exception of defects in parts on the drive train/gear box on EM and GM sprayers or power train on EH and GH
sprayers, which will be repaired or replaced for twenty-four months from the date of sale for Gas–Hydraulic (GH) and Gas-
Mechanical (GM) sprayers and for thirty-six months from the date of sale for Electric-Mechanical (EM), Electric-Hydraulic (EH),
390st and 490st sprayers

.

 This warranty applies only when the equipment is installed, operated and maintained in accordance

with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation,
misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco
equipment of structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, instal-
lation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor
for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any
defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts,
labor and transportation.

DISCLAIMERS AND LIMITATIONS

The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties (express or
implied), 

including warranty of merchantability or warranty of fitness for a particular purpose,

 and of any non–contractual

liabilities, including product liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequen-
tial damages or loss is expressly excluded and denied. In no case shall Graco’s liability exceed the amount of the purchase price.
Any action for breach of warranty must be brought within two (2) years of the date of sale.

EQUIPMENT NOT COVERED BY GRACO WARRANTY

Graco makes no warranty, and disclaims all implied 

warranties of merchantability and fitness for a particular purpose

, with

respect to accessories, equipment, materials, or components sold but not manufactured by Graco. These items sold, but not
manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer.
Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

ROBERTS CONSOLIDATED INDUSTRIES, INC.
P.O. Box 1250 / 600 N. Baldwin Park Blvd.
City of Industry, California 91749
(213) 338–7311 or (800) 423–9467

PRINTED IN U.S.A. 308–021 November, 1989; Revised December, 1994

Содержание 61-251

Страница 1: ...tting safety latch when not spraying Never spray without a tip guard In case of accidental skin injection seek immediate Surgical Treatment Failure to follow this warning can result in amputation or serious injury FIRE AND EXPLOSION HAZARD SKIN INJECTION HAZARD READ AND UNDERSTAND ALL LABELS AND INSTRUCTION MANUALS BEFORE USE Spray painting flushing or cleaning equipment with flammable liq uids in...

Страница 2: ...ty lever in the locked or inoperative position TRIGGER View from front of gun Diffuser The gun diffuser breaks up spray and reduces the risk of fluid injection when the tip is not installed Check diffuser operation regularly Follow the Pressure Relief Procedure below then remove the spray tip Aim the gun into a metal pail holding the gun firmly to the pail Using the lowest possible pressure trigge...

Страница 3: ...ined hose length to ensure grounding continuity See Hose Grounding Continuity below 3 Spray gun obtain grounding through connection to a prop erly grounded fluid hose and sprayer 4 Object being sprayed according to local code 5 Fluid supply container according to local code 6 All solvent pails used when flushing according to local code Use only metal pails which are conductive Do not place the pai...

Страница 4: ...raulic oil use only Graco Hydraulic Oil Part No 218 797 Install the fill cap See Fig 1 5 Check the electrical service It must be 120 VAC 60 Hz 15 Amp minimum Be sure the electrical out let is properly grounded You can use up to 100 foot 30 m of 3 wire 14 gauge minimum extension cord Longer exten sion cords may affect the sprayer performance Use more spray hose not longer extension cords Do not rem...

Страница 5: ... pail of adhesive 5 Turn the sprayer ON and allow the adhesive to circu late through the bypass valve 4 for one or two min utes NOTE If the adhesive does not circulate back into the pail turn down the pressure and turn the motor on and off several times to help prime the sprayer 6 Turn the bypass valve 66 clockwise finger tight to close it this allows the pump to build up pressure 7 Release the tr...

Страница 6: ...rs thereafter about weekly Check or change the hydrau lic oil 1 Check the oil after each use of the sprayer 2 Change the oil after the first 20 hours of operation 3 Change the oil each 50 hours thereafter about twice monthly Replace the diaphragm After every 500 gallons of fluid sprayed 4 to 6 months Tighten the Fluid Pump Screws and Inlet Valve See Fig 5 1 Follow the Pressure Relief Procedure on ...

Страница 7: ...r to drain the adhesive Now turn off the sprayer See Fig 8 2 Place the fluid pump in a grounded pail of solvent 3 Check to be sure the trigger safety lever is locked Remove the spray tip from the gun Unlock the safety lever Hold a metal part of the gun firmly to the side of a grounded metal pail Close the bypass valve Trigger the gun into the pail T urn on the sprayer Watch the side of the pail fo...

Страница 8: ...ween needle and diffuser Disassemble and clean gun Spray gun leaks Worn seal or loose fluid fitting Repair gun order Kit no 218 588 tighten fluid fitting Spray gun won t spray or low output from gun Fluid supply empty Refill and reprime system Spray tip clogged Use Reverse A Clean feature to clear tip clog see page 12 Gun filter if used is clogged Clean or replace Sprayer will not start Sprayer no...

Страница 9: ...p Replace Sprayer sucks fluid builds pressure but pressure drops when gun is trig No spray tip on gun Shut off sprayer and install tip but pressure drops when gun is trig gered Spray tip orifice too large for the fluid or worn tip Try a smaller tip or a new tip Inlet screen clogged Clean Optional gun filter clogged Clean or replace Optional gun filter screen too fine for type of fluid Install larg...

Страница 10: ...e will cause performance problems 6 Install the housing 28b and torque to 125 150 in lb 14 17 N m 7 The last coil on one end of the spring is turned in Place this end over the stud in the plug 28d Install the ball 28e washer 28f and plug and torque to plug to 380 300 in lb 32 34 N m Pressure Control See Fig 10 When removing the pressure control 4 to check or clean it always replace the seal 4a Whe...

Страница 11: ...n it on Run the sprayer for two minutes to fill the hydraulic sys tem Increase the pressure to maximum and turn the sprayer on and off four times to help rid the hydraulic system of air Fig 10 21 22a 22b 26a 26 27 25 24 28d 28f 28c 28e 28b 28a C 4 4a 38 37 36 66 35 3 67 20 28 18a 0284 1 3 4 2 Torque to 125 150 in lb 14 17 N m Apply sealant to the threads Lubricate the internal threads Torque to 12...

Страница 12: ... 4 2 Lubricate the threads Torque to 40 45 in lb 54 60 N m Torque to 130 140 in lb 15 16 N m Apply tape to the top and bottom threads See Detail A page 14 Torque to 70 90 in lb 8 10 N m The tube must drop freely in the pipe 1 Apply sealant to the threads The seal in the bearing must face down Apply threads sealant to the motor tie bolts See Detail B on page 14 5 7 8 6 10 3 2 5 7 8 6 10 1 4 83 9 9 ...

Страница 13: ...G cylinder 1 42 183 840 CYLINDER pump 1 43 108 153 FITTING hose barbed 1 44 107 511 SPRING compression 1 45 180 479 PISTON 1 46 180 480 WASHER spring 1 47 107 517 RING retaining external 1 48 107 524 RING retaining external 1 49 107 513 KEY woodruff 1 50 218 909 ECCENTRIC ASSEMBLY 1 52 108 042 SCREW cross head recessed M4 x 14 0 8 53 180 650 GASKET housing 1 54 107 518 BEARING ball 1 55 107 519 SE...

Страница 14: ...G compression 1 28d 218 505 PLUG ball stop 1 28e 112 618 BALL carbide 1 28f 180 454 WASHER 1 68 186 334 ADAPTER tip 1 93 166 969 WASHER 1 94 110 761 TIP spray 16 fan 0 031 orifice 1 96 220 251 TIP GUARD Includes washer item 93 1 98 223 541 HOSE coupled 1 4 x 50 1 99 204 940 SWIVEL straight 1 100 214 701 HOSE coupled 3 16 x 3 1 101 222 002 GUN Basic see 307 821 for parts 1 102 218 245 TUBE extensio...

Страница 15: ...A for the best visiblity Order the labels directly from your Graco distributor without charge Call 1 800 328 0211 A Manual Change Summary Assembly Changed Part Status Ref No Part No Part Name Model 61 251 Sprayer Old New Old New Delete Delete Add Add 27 27 28 28 28c 28e 28c 28e 108 143 218 798 218 732 236 954 107 521 101 701 112 619 112 618 Strainer Strainer Outlet valve Outlet valve Spring Ball S...

Страница 16: ... non Graco component parts Nor shall Graco be liable for malfunction damage or wear caused by the incompatibility with Graco equipment of structures accessories equipment or materials not supplied by Graco or the improper design manufacture instal lation operation or maintenance of structures accessories equipment or materials not supplied by Graco This warranty is conditioned upon the prepaid ret...

Отзывы: