EN
EN - 27 -
SYMPTOMS
POSSIBLE REASONS
SOLUTIONS
Display OFF
Display
switches on
when button
is pressed
Display auto off mode activated Fixture tools menu
→
Display mode
(see page EN-20)
Display still off
when button
is pressed
No power
Check :
• power supply
• thermal protection
• the power supply connector must
be properly interlocked
System and data display
7
switched on
in red (see page EN-19)
Problem with the DMX512
received signal and/or system
default – details available in
4/6
Fixture Tools
menu
Failure details are available in section
4.10.2,
menu
4/6 Fixture Tools
menu
The unit cannot be
controlled via DMX*
(inactivated wireless
DMX)
Data display
7
switched on
in red
DMX protocol problem
Check data signal
The received
data protocol can
be checked in
the Fixture tools
menu
Data cabling problem
Check cabling and data
connectors
Data display
7
switched on in
green
DMX address
Check the DMX address
The strobe is active and the
channel value is void
The value must be 255 (100%) in order to
have the light intensity dimmed
When using several units, dimming are
not synchronized
Different Resolution
The value must be 255 (100%) in order to
have the light intensity dimmed
Different smoothing
All the units must have the same smoothing
(See section
4.10.2,
menu
3/6
Fixture param
menu
→
Smoothing
)
Different Dimming curve
All the units must have the same dimming
curve (See section
4.10.2,
menu
3/6
Fixture
param menu
→
Light
Curve
)
Light switches on when powered on
Manual value is operating when
DMX is not connected
Local values must be at zero
Light switches on when using the control
board
Use of the Focus mode
See page EN-12, section
4.1.2
Strobe function doesn’t work
Strobe function inactive
Strobe must be activated in Fixture param.
menu
→
Strobe Control
Strobe function active
Control channel must be higher than 0
6 Troubleshooting
(*)
NOT available for the Variable White version.
Содержание TIBO 533 CW
Страница 13: ...EN EN 11 3 3 4 Optics Step 1 Step 2 Zoom 30 45 Zoom 15 35 Step 3...
Страница 21: ...EN EN 19 4 9 2 Iris Type Standard iris Dimensions Installation See section 3 3 2 10 mm 42 5 mm...
Страница 41: ...FR FR 11 3 3 4 Optique Zoom 30 45 Zoom 15 35 Step 1 Step 2 Step 3...
Страница 49: ...FR FR 19 4 9 2 Iris Type Iris standard Dimensions Installation Cf 3 3 2 10 mm 42 5 mm Valeurs en mm...