Robert Juliat SULLY 1156 Скачать руководство пользователя страница 3

EN

 EN - 1 -

GENERAL INSTRUCTIONS

1.  Not for residential use.
2.  These fixtures must only be serviced by a qualified technician.
3.  In addition to the instructions indicated on this page, relevant health and safety requirements of the appropriate EU
 

Directives must be adhered to at all times.

4.  This fixture is in compliance with section 17 - Lighting appliance for theatre stages, television, cinema and photograph studios.
 

Standards NF EN 60598-1, NF EN 60598-2-17, Low Voltage Directive 2014/35/UE & EMC Directive 2014/30/UE.

5.  This fixture is rated as IP20, and is for indoor use only.

FIXTURE

6.  Ensure fixture is correctly mounted on an appropriate support.
7.  Protection screens and lenses must be replaced in the event of any damage, such as cracks or deep scratches, since these might
 

reduce performance.

8.  When hung or flown the fixture must be secured by an additional hanging accessory (such as a safety cable or bond) of suitable
 length. 
9.  Safety bonds or cables must be securely attached to the back of the fixture and be as short as possible, or rolled up as necessary, 
 

to minimise travel distance should the fixture be dislodged.

10.  Movable accessories (scroller, etc.) must also be secured with a suitable safety cable or bond at the front of the fixture.
11.  The combined weight of both the fixture and the accessories must be considered when choosing the load-bearing capability of 
 

safety cable or bond.

12.  Do not open lighting fixture when the source is on.
13.  WARNING: LED source become hot during use. Allow fixture to cool before servicing.
14.  Do not tamper with design of fixture nor any of its safety features.
15.  Tighten electrical mains cable connections regularly and replace with one of identical specification if damaged.
16.  Use only with correct power supply.

VENTILATION

17.  Keep well away from flammable material.
18.  Not for outdoor use. Do not cover. Do not permit fixture to get wet.
19.  To avoid overheating, do not obstruct air vents.
20.  Ensure any cooling fans are in correct working order. If fans are not working, turn fixture off immediately and service as necessary.

CLEANING

21.  Do not touch the LED source with your fingers.
22.  To clean the optical parts, use a soft cloth in combination with distilled water or isopropyl alcohol recommended for coated optics. 
 

Do not use any cleaning product that contains solvents or abrasives, as these can cause surface damage. Dry with a soft lint-free cloth.

23.  Regularly remove dust with a soft lint-free cloth.
24.  If the fixture has filters, they must be cleaned frequently.

POWER SUPPLY

25.  Disconnect from the mains before servicing.
26.  Mains connection only. Do not connect to "electronic output" such as dimmer.
27.  Ensure power supply circuit breakers, always remain accessible.

PLEASE NOTE

This product has been built to conform to European standards relating to professional lighting equipment. 
Any modification made to our products will void the manufacturers' warranty.

1 User’s instructions

Minimum 

distance

Risk 

group 2

0,8m 

(

2.63 ft

 )

10,6m 

(

34.78 ft

 )

Risk 

group 1

Photobiological safety according to EN62471

Risk group 2

CAUTION:

 Possibly hazardous optical

radiation emitted from this product.
Do not stare at operating lamp. 
Maybe harmful to the eye.

Group risk 2. Luminaires should be positioned so that 
prolonged staring into luminaire at a distance closer than 
10,6m is not expected.

Содержание SULLY 1156

Страница 1: ...bertjuliat fr www robertjuliat com LED FOLLOWSPOT DN41202000 EN 115 W FOLLOWSPOT Model Standard North American 10 5 22 5 Warm White 1156WW 1156CWW 10 5 22 5 Cool White 1156CW 1156CCW VALIDATION 14 04...

Страница 2: ...de 15 4 2 Strobe 15 4 2 1 Range 15 4 2 2 Control 15 4 3 Response time 15 4 3 1 Range 15 4 3 2 Control 16 4 4 Beam size adjustment 16 4 4 1 Range 16 4 4 2 Control 16 4 5 Orientation 17 4 5 1 Range 17 4...

Страница 3: ...of fixture nor any of its safety features 15 Tighten electrical mains cable connections regularly and replace with one of identical specification if damaged 16 Use only with correct power supply VENT...

Страница 4: ...ensity Ampere A Voltage Volt V Frequency Hertz Hz Temperature degree Celsius C 1 MOD Model 2 VERS Version 3 U Nominal voltage input V 4 I Nominal intensity A 5 P Maximum power input W 6 IP Internation...

Страница 5: ...lass or frosted glass 5 IS750 Full closing iris with holder 6 PF1114 165 mm metal filter holder x6 7 M165TP 6 way push pull colour changer Description Units Weight kilogram kg Intensity Ampere A Volta...

Страница 6: ...716A 16A blue 2P E 6h IEC60309 power connector 9 T 1650SXCW SULLY 115W LED compartment with potentiometer Cool White 3 meter power cable with CEE 7 7 2P T NF SCHUKO connector 10 T 1650SXWW SULLY 115W...

Страница 7: ...1 Operating positions 3 1 2 Minimum distance between a flammable material and the lighting unit 3 1 3 Instructions for use 3 1 4 Lifting Net weight 15 6 Kg 34 3 lbs Minimum 40 C 104 F 5 C 40 F IP20 In...

Страница 8: ...ver touch or scratch the LED surface See 6 1 4 LED cleaning procedure if cleaning is necessary 3 2 2 Power supply Class 1 product This luminaire must be earthed Must be connected directly to AC power...

Страница 9: ...an version 14AWG SJ TYPE UL CSA 1 5 m 4 9 ft Live Black Neutral White Ground Green DATA connectors PIN DMX Description 1 Shielding Foil Braided Shield 2 DMX 1st conductor of 1st twisted pair 3 DMX 2nd...

Страница 10: ...rratic behavior of all connected devices For further reading https en wikipedia org wiki Internet_Group_Management_Protocol RJ LED2 FIRMWARE PLATFORM Node Mode full manual is available for download at...

Страница 11: ...EN EN 9 3 4 Accessories 3 4 1 Iris Gobo For filter dimensions see section 4 7 Click Correctly in place Iris Gobo holder Filter holder 3 4 2 Gobo holder Click Correctly in place...

Страница 12: ...EN EN 10 3 4 3 Internal filter holder For filter dimensions see section 4 8 3 4 4 Colour changer unit push pull Gel filter DImensions see section 4 8 Paper fastener Parisien 3 pieces on each frame...

Страница 13: ...EN EN 11 For filter dimensions see section 4 8 Front filter holder Safety grid 3 4 5 Double slot front cassette for front accessories option...

Страница 14: ...EN EN 12 For full procedure see page EN 29 APH68 LED only possible with LED version not with halogen 3 4 6 Double condenser set...

Страница 15: ...3 4 Operations 4 1 Light intensity 4 1 1 Range 4 1 3 Parameters 4 1 3 1 Dimming resolution DMX only T Set through RDM protocol or web interface Resolution DMX mode 8 bits 255 steps 1 3 16 bits 65 535...

Страница 16: ...channel can be used This channel limits the maximum value of the dimmer shutter By using this function it is possible to obtain synchronised fades with several spots or to give intensity limits minim...

Страница 17: ...n Strobe speed 4 2 2 Control 0 OFF 0 0 1Hz 1 1ms 255 20ms 255 10Hz T Remotely with DMX512 A Art Net sACN protocols Mode 3 4 4 1 3 5 Dimming mode T Set through RDM protocol or web interface Mode Result...

Страница 18: ...70 ms FAST 350 ms CUSTOM 0 4000 ms or RDM Web interface RDM compatible device DMX512 A EN 16 4 3 2 Control T Remotely with DMX512 A Art Net sACN protocols Mode 3 4 Model Minimum angle Maximum angle 11...

Страница 19: ...EN Lock Unlock EN 17 Function Range PAN 0 T 360 TILT TU 0 T 38 TD 0 T 56 4 5 Orientation 4 5 1 Range 4 5 2 Control...

Страница 20: ...e Type Coloured gel filter Dimension Installation See 3 4 4 Type Standard gobo A size Dimensions Installation See 3 4 3 4 8 Colour Fixed colour place dark colours towards the rear end 4 8 1 Range 72 m...

Страница 21: ...EN EN 19 Location 1 Internal filter holder 2 Front filter cassette option Type Frosted or dichroic glass Coloured gel filter option Dimensions Installation See 3 4 3 See 3 4 5 1 2...

Страница 22: ...r must be on the same network as the Sully followspot Please refer to your computer Operating System to change IPV4 parameters Microsoft Windows https support microsoft com en us windows change tcp ip...

Страница 23: ...of your device is indicated If unknown please select the CCT of your device and click on icon or then on the arrow Changing the source type changes the Model_ID as well It is used in libraries to rec...

Страница 24: ...Ethernet detected link Ethernet detected data No DMX protocol detected No ethernet Ethernet detected link Ethernet detected data Unit error 1 DMX OUT 2 DMX IN 3 Network Description Unit OFF Unit erro...

Страница 25: ...5 3 1 Protocol E1 11 2008 USITT DMX512 A 5 3 2 Configuration 5 3 3 Parameters 5 3 3 1 DMX Hold If data not detected Hold last values Default value Standalone value Reset DMX values T Set through RDM p...

Страница 26: ...robe duration 6 Control mode Control mode Strobe speed 7 Response time 8 Control mode 5 3 5 DMX ranges 5 3 5 1 Strobe duration 5 3 5 2 Strobe speed 5 3 5 3 Response time 5 3 5 4 Control mode Function...

Страница 27: ..._DETAIL_ID_LIST X X 00 80 DEVICE_MODEL_DESCRIPTION X X 00 81 MANUFACTURER_LABEL X X 00 82 DEVICE_LABEL X X X X 00 90 FACTORY_DEFAULTS X X X X 00 C0 SOFTWARE_VERSION_LABEL X X X 00 C2 BOOT_SOFTWARE_VER...

Страница 28: ..._IP_ADDRESS X X X 85 5A CURRENT_NETMASK X X X 85 5B CURRENT_DRIVER_STATUS X X X 85 5C CUSTOM_RESPONSE_TIME_DESCRIPTION X X 85 5D CUSTOM_RESPONSE_TIME_VALUE X X X X 85 60 DATA_MODE_DESCRIPTION X X 85 6...

Страница 29: ...terface 1 If necessary change IP settings 2 Set ArtNet parameters Net SubNet Universe 3 Set DMX address 2 Set personality mode see 5 3 4 DMX chart 5 6 sACN remote control 5 6 1 Protocol ANSI E1 31 200...

Страница 30: ...system aspheric and biconvex lenses can easily be removed without tools by loosing the two wing nuts The complete holder can then be removed for cleaning Lens tube access 6 Service 6 1 Preventive main...

Страница 31: ...ED compartment and remove the earth attachment before removing it completely from it s housing 5 Carefully place the LED compartment on a flat clean surface Sully LED compartment installation 6 Extend...

Страница 32: ...you will have to stay on the Web Page that you used for the update In the Source section of the HOME tab the CCT of your device is indicated If unknown please select the CCT of your device and click o...

Страница 33: ...en click on Submit firmware 6 5 Factory defaults 6 5 1 Modes 6 5 2 Control T If IP address unknown due to a previous modification IP address can be read from RDM protocol or a hard reset must be done...

Отзывы: