robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thellle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat reserve the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
VALID SINCE
: 25.06.01
20
DOSSIER TECHNIQUE
HMI PROFILE 1200W & 2500W
DocT
ech_900SNX_0601.ind
900 SNX
CONNECTION.
a
b & f
e
CAD 900/Mechanical Shutter cable.
CAD 900 side.
FM XLR 7.
Shutter side.
FF XLR 7.
Flexible cable
14 x 0,14 shielded
CN14.
1 0V. GND.
2 Lamp circuit.
3 Shutter circuit.
4 +15V.
DESIGNATION
REP
d
c
Flexible cable
5 x 0,14 shielded.
FF XLR 4.
0/+10V control.
1 0V.
2 DATA - IN.
3 DATA + IN.
4
5
DESIGNATION
REP
1 0V.
2 DATA - OUT.
3 DATA + OUT.
4
5
DESIGNATION
REP
Flexible cable
5 x 0,14 shielded
CN5.
FF XLR 5.
FM XLR 5.
Flexible cable
5 x 0,14 shielded
CN5.
DATA Link.
Delivered standard : 3m.
0V.
DATA -
DATA +
PWM
INFO 0/+10V
+U
- U
/
DESIGNATION
REP
1 0V.
2 DATA -
3 DATA +
4 PWM
5 INFO 0/+10V
6 +U
7 - U
NC /
DESIGNATION
REP
4 x 0,14
1 x 0,14
1 x 0,14
1 x 0,14
1 x 0,14
3 x 0,14
3 x 0,14
Shielded
1
2
3
4
5
6
7
SHELL
k
L Phase
N Neutral
Earth
DESIGNATION
REP
SELECT
EXIT
+
C A D 900
a b c d
h
k
e
f
250V. 10A. EEC male mains connector
for power feed for the fan.
1 Fan phase.
2 Ballast phase.
3 Lamp Neutral.
4
5
6 Security return 1200.
7 Security return 2500.
8 Security not used.
9 Ignition timed phase.
10 Ballast phase.
11 Lamp Neutral.
12 Earth.
13 Aux. phase.
14 Aux. Neutral.
15 Common security.
16 Earth.
Female side earth only.
Lamp cable.
Ballast side.
FMD 16 x16 A
HARTING.
Lighting unit side.
FFD 16 x16 A
HARTING.
Cable H07 RN-F
19 G 1,5.
REP
DESIGNATION
DESIGNATION
REP
Delivered standard : 3m.
Note:
This is a universal cable and is suitable for a follow spotlight
or a profile, 1200W. or 2500W.
g
h
Содержание SNX 900 Series