DOSSIER TECHNIQUE

1200W MSR/MSD COLD STRIKE FOLLOW SPOTS

D

oc

Te

ch

10

19

C

S_

C

C

S_

06

01

.in

d

ADMISSIBLE LAMPS :-

PHILIPS: MSR 1200 - MSR 1200/2 - MSD 1200

OSRAM: HSR 1200 - HSR 1200/2

Manufacturer's recommendations:

• Read attentively the manufacturer's instructions. 

• Positioning of the lamp and connecting of the power supply require great care. To make sure there is a good

  conduction of current, the mechanical support and the electrical connections must be free form dirt and corrosion.

  The clamps and brackets must be checked whenever the lighting unit has been transpoted.

• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.

• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.

• Use only when bulb in place

Technical characteristics:

User's precautions:

• The lamplife, as given by the manufacturer, is an theoretic lamplife duration as "in laboratory conditions" a cycle    

  based on 3 hours on / 1 hour off, cycles more brief, reduce the duration of the lamplife.

• Premature wearing of lamp under performing conditions, is mainly due to frequent switching on. Better to leave

  the lamp on, through the performance, rather than switching it on repeatedly. ( The lampelife is reduced about 

  1 hour, each time the lamp is lighten ). 

• 

Use over 500 hours of the lamp : change the lamp even thou it still lights up.

  (For MSR 1200 - HSR 1200 and MSR 1200/2 - HSR 1200/2 lamps).

New lamp:

• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on 

   for a few hours.

• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event of a dispute.

                                                                                               Thank you.

1019 CS & CCS

1119 CS & CCS

1419 CS & CCS

Follow spot description :

CS - RANGE

CCS - RANGE

Voltage use :

(European Standard) 230/245 Volts. 50Hz.

Voltage use :

(North American standard) 208 Volts 60Hz.

110 Volts 60Hz.

Minimum voltage supply :

198 Volts

105 Volts

(Below this charge = possible ignition failure).

Lamp description :

MSR 1200

MSR 1200/2

MSD 1200

HSR 1200

HSR 1200/2

Nominal adsorbed wattage :

1200 Watts

1200 Watts.

1200 Watts

Lamp voltage :

100 Volts

100 Volts

100 Volts

Lamp current :

13,8 Amps

13,8 Amps

13,8 Amps

Base :

G 22

G 22

G 22

Lumen output :

110 000 L's

110 000 L's

92 000 L's

Colour temperature :

5900 Kelvin

7200 Kelvin

6000 Kelvin

Manufacturer's rated life :

800 Hours

800 Hours

2000 Hours

Содержание 1019 CCS

Страница 1: ...POURSUITES MSR MSD 1200W AMORCAGE A FROID 1200W MSR MSD COLD STRIKE FOLLOW SPOTS MARIUS 1019 CS 1019 CCS TOPAZE 1119 CS 1119 CCS MANON 1419 CS 1419 CCS robert juliat Route de Beaumont F 60530 Fresnoy...

Страница 2: ...NOTES...

Страница 3: ...t Ne manquez pas de nous faire part de vos id es ou suggestions c est gr ce vous que le produit pourra voluer Merci de votre attention ROBERT JULIAT You have in your possession a ROBERT JULIAT follow...

Страница 4: ...amp 16 Changing the colour frames and colours 16 Switching on 17 B MAINTENANCE Aspheric lens reflector 17 Electrical diagram lantern 18 Electrical diagram P S U 1200W 19 C SPARE PARTS LIST 6 way colou...

Страница 5: ...place de la lampe 16 Echange des porte filtres et des g latines 16 Mise en marche 17 B ENTRETIEN Lentille asph rique miroir 17 Sch ma lectrique lanterne 18 Sch ma lectrique alimentation 1200W 19 C NO...

Страница 6: ...ed at the back of the unit This must be mounted as short as possible or rolled up a few times if needed Their movable accessories barn doors HMI shutters must also be safety assured with a suitable se...

Страница 7: ...n devra tre effectu e au plus court au besoin avec plusieurs tours si la longueur de l lingue ou de la cha ne le n cessite Les accessoires amovibles coupe flux volets HMI doivent galement tres assur s...

Страница 8: ...that has 2 holes on its yoke 3 Lighting unit that has 1 central hole on its yoke 4 First remove the two bolts 5 before mounting Remove the knobs 6 Place the yoke vertically towards the bottom 7 Place...

Страница 9: ...rte 2 trous de fixation 3 Projecteur dont la fourche comporte 1 seul trou central 4 retirer les 2 goujons inutilis s 5 Retirer les boutons 6 Positionner la fourche verticalement vers le bas 7 Position...

Страница 10: ...lamp terminal IP 20 indoor use ONLY t a surrounging temperature t max External maximum temperature of the unit 7 Restrictive position use front view 8 Minimum distance between a flammable material and...

Страница 11: ...max IP 20 utilisation int rieure uniquement t a temp rature ambiante t max temp rature maximum ext rieure de la carrosserie 7 Positions restrictives d utilisation en vue de face 8 Distance minimum d u...

Страница 12: ...ing unit s power cable C to the P S U 1 Place the lamp into position refer to page 16 Connect the cable 2 to the mains CAUTION For your security Never open the lantern s bonnet when the lighting unit...

Страница 13: ...on Raccorder le c ble C sur l alimentation 1 Mettre la lampe en place voir page 16 Raccorder le c ble 2 au secteur ATTENTION Pour votre s curit Ne jamais ouvrir les portes de lanterne projecteur allum...

Страница 14: ...y conditions a cycle based on 3 hours on 1 hour off cycles more brief reduce the duration of the lamplife Premature wearing of lamp under performing conditions is mainly due to frequent switching on B...

Страница 15: ...un cycle de 3 heures allum es 1 heure teinte des cycles plus brefs r duisent la dur e de vie L usure pr matur e de la lampe en utilisation spectacle est essentiellement due la fr quence des amor ages...

Страница 16: ...e User s precautions Disconnect from the mains Wait until lamp is cold when replacing Avoid touching the bulb of the lamp Ouvrir le capot de la lanterne Appuyer 1 pour lib rer les m choires de la doui...

Страница 17: ...LENTILLE ASPHERIQUE MIROIR S assurer d tre hors tension Ouvrir le capot de la lanterne Sortir la lampe Voir notice page 16 Desserrer le verrou 1 Retirer l ensemble porte lentille 2 Essuyer la lentille...

Страница 18: ...IGNITER MSR MSD HSR 1200W BAG ELECTRONIC TERRE EARTH NEUTRE NEUTRAL PHASE SELF CHOKE PHASE DIRECTE DIRECT ME15100013 VENTILATEUR FAN PASPT 230V AC 13W 120 120 40 4580Z ME14220202 ME06200407 1019P1200...

Страница 19: ...1010203 Pour For version 110V C Disjoncteur 25A Automatic breaker 25A ME01025301 K Autotransformateur Auto transformator ME05011023 Entr e input 110V 60Hz Sortie output 208V 60Hz L Ventilateur Fan 489...

Страница 20: ...11P30102 1011P30105 DJ30484210 CF00300034 PD10110015 PD10110014 1017P30000 1011P30002 DJ30484210 PD10110008 PD10110007 DJ40211601 1011P30006 PD14390004 PD10110009 DJ30032201 1011P30004 Changeur 6 coul...

Страница 21: ...025 1039P20005 OP11010005 DE40557000 DE30563501 DE30563502 1019P21001 PD10170005 DT40572800 DJ40566002 DJ40566001 DU40264500 VI03010008 BO06000005 DU30222015 VI04010012 VI04030010 DU40565400 FPADIV003...

Страница 22: ...5 x 5 x L8 Rondelle inox de pression Pressure washer Colonnette Strut F F M4 x 63 5 Vis Screw M4 x 16 Miroir Reflector 90 R60 Plaque de support Reflector support Entretoise Strut 3 2 x 3 5 Entretoise...

Страница 23: ...ST CODE DESCRIPTION REP DocTech1019CS_CCS_0601 ind 23 POURSUITES MSR MSD 1200W AMORCAGE A FROID 1200W MSR MSD COLD STRIKE FOLLOW SPOTS Mesures en mm Measurements are in mm 18 06 01 1200W G22 Pi ces sp...

Страница 24: ...F M3 x 6 Bouton Knob M6 Colonnette Strut M3 Ecrou Nut M3 Ressort Spring Rondelle plate Washer s rie L 4 Ecrou frein fendu Safety nut M4 Plaque porte galet Roller support Rondelle Washer Vis Screw CHC...

Страница 25: ...6 01 ALIMENTATION POWER SUPPLY UNIT VUE DE FACE FRONT VIEW ME12020105 ME01015202 ME01025301 ME01010203 ME01002201 COU0004206 COU0003250 PD60000001 700A010001 1200A01004 CE01100K01 ME05021034 CE0380U00...

Страница 26: ...ompl te seule Complete stopping device 2 BO04010005 Ecrou molet seul Milled nut only 3 CF00100018 Embout de rotule Ball socket 4 CF00100019 Cabochon d embout de rotule Ball socket cap B RPAFIX0062 Ens...

Отзывы: