robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing techniques without prior notice.
VALID SINCE
: 20.10.03
DocT
F_CF_1003.ind
12
TECHNICAL FILE
1200W HMI FOLLOW SPOT
COLD RESTRIKE
PUTTING THE LAMP INTO PLACE.
User's precautions:
-
Disconnect from the mains.
- Lamp is cold.
- Avoid touching the bulb of the lamp.
- Open the bonnet and the side covers of the lantern.
- Use only when lamp is in place
Preparation of the lamp:
- Unscrew the nuts 1 without taking them off completely.
Putting the lamp into place :
- Place the lamp into the contacts 2 ,
the tip-off upwards and toward the back D .
- Tighten the nuts 1 firmly, by hand.
Warning :
A badly tighten lamp can cause
a bad contact and a defective
ignition. Check regularly that the
nuts 1 are well tightened.
Lamp
.
Warning :
Do not use a lamp, if the diameter
of the bulb is greater than Ø28mm.
SWITCHING ON.
- Engage the main automatic breaker a towards the top.
The mains checklight b lights up.
- Engage the automatic breaker c towards the top, if you
are using the power socket d .
Warning
:
Carry out the connections before
connecting to the mains ( refer to page 10 ).
Ø28 maxi
180
1
2
2
1
A
B
C
E
D
A
B
C
D E
Disconnect from the mains before any servicing.
Service only by qualified technician.
a
b
c
d
230V.
50Hz
1011+ F & 1011+CF
Содержание 1011+ F
Страница 2: ...NOTES...