background image

SS550 Métallique 30” High Cabinet

 

4. Recess Cabinet

1.  The rough opening must be at least 4” deep cabinets 

  when fully recessed and must be framed on all 4 

  sides important!
2.  The chart shown below is the overall size and rough  

  openings for recessed installations.

3.  Place the single or connected boxes into the rough  

  opening. Be sure the bottom is level. Install a #10 X  

  3” pan head screw through the top hole shown  

  in figure J on page 4.
4.  Be sure cabinet is square. Install bottom screws. 

  Do  not over tighten screws.
5.  Place grey caps over screw heads.
6.  Install doors following the instructions supplied with  

  the hinge and shown in figure J on page 4.
7.  Open and close doors to check operation. On  

  installation of the cabinets in combinations of three 

  or more the center door when open may cause the 

  cabinet to bow from the wall. If this occurs install a 

  #10 X 2” Or 3” SMS/Wood screw and cap through 

  a hole drilled at the location shown in figure F. 

#10 X 3" 

SMS/ WOOD

SCREW

 CABINET 

Snap-in Shelf Clips

A. Push one side of the

    shelf into the left or 

    right clips.

B. Snap the shelf down

    into the opposite

    side. If the shelf is

    too tight, repeat the

    process from the

    other side.

5. Assembly of Ganged Cabinets

1.  Each cabinet and side kit contains special connectors 

  to allow combinations of cabinets. Both surface  

  mounted using the SK Side Kits as well as recessed  

  into the wall. (See figure H.)
2.  With the doors off, combine the boxes with the proper 

  connectors to assemble the units per your layout. Use 

  the #10 X 1/2” thread cut screws. (See figure H and I.)
Assemble on a convenient flat surface. Not on or in wall.
Do not attach lights, doors or side kits until boxes are 

secured to wall.
Note location of holes in the cabinets which are used to 

secure connectors and side kits in figure J on page 4.

MT20D4MD

MT20D4MD

#10 X 1/2"

SCREWS

USE MTSK30

SIDE KIT FOR 

SURFACE MOUNT.

TWO CABINET COMBINATION FOR RECESS INSTALLATION.

 CABINET 

 CABINET 

MP65 CONNECTOR

Shelf Installation

Model No. 

Overall  

Wall Opening

MT20D4MD 

19 1/4” X 30” 

18 1/2” x 29 1/4”   

MT24D4MD 

23 1/4” x 30” 

22 1/2” x 29 1/4”

Fig. E

Fig. F

Fig. H

DRILL 7/32"  THRU TOP

OF MIDDLE CABINET

3/4" FROM BACK AND 

HINGE SIDE AS SHOWN

WHEN THREE OR MORE

CABINETS ARE RECESSED.

3/4"

3/4"

Fig. G

Fig. I