Robe Stage Banner 10 AT Series Скачать руководство пользователя страница 7

6

7

4.3 Rigging the fixture

DANGER TO LIFE!

 

Please consider the respective national norms during the installation! 

 The installation must only be carried out by an authorized distributor!

The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. 

This secondary safety attachment must be constructed in a way that no part of the installation can fall down if 

the main attachment fails.

When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, 

under high working places and other endangered areas is forbidden.

The operator has to make sure that safety-relating and machine-technical installations are approved by an expert 

before taking into operation for the first time and after changes before taking into operation another time.

The operator has to make sure that safety-relating and machine-technical installations are approved by an 

expert after every four year in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled 

person once a year.

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to) 

calculating working load limits, installation material being used, and periodic safety inspection of all installation 

material and the device. If you lack these qualifications, do not attempt the installation yourself, but instead use 

a professional structural rigger. Improper installation can result in bodily injury and.or damage to property.

The device has to be installed out of the reach of people.

If the device shall be lowered from the ceiling or high joists, professional trussing systems have to be used. 

The device must never be fixed swinging freely in the room.

Caution: 

Devices may cause severe injuries when crashing down! If you have doubts concerning the safety of 

a possible installation, do NOT install the device!

Before rigging make sure that the installation area can hold a minimum point load of 10 times the device’s 

weight.

CAUTION !

 

Provide a minimum clearance of 0.1meters around fans and air vents.

CAUTION!

 

 

Use 2 appropriate clamps to rig the device on the truss.   

 

 

 

 

 Maximum load of the fixative plate is 10 kg.   

 

 

Make sure that the device is fixed properly! Ensure that the 

structure (truss)to which you are attaching the fixtures is secure.

The device can be placed directly on the stage floor or rigged in any orientation on a truss without altering its 

operation characteristics .

For overhead use, always install a safety-rope that can hold at least 10 times the weight of the device. You must 

only use safety-ropes with screw-on carabines. Pull the safety-rope through the two apertures on the bottom of 

the base and over the trussing system etc. Insert the end in the carabine and tighten the fixation screw.

Содержание Stage Banner 10 AT Series

Страница 1: ...1 Version 1 1 ...

Страница 2: ... 10 AT DMX Protocol version 1 0 10 6 Operating modes 11 6 1 Controller mode 11 6 2 Stand alone mode 11 7 Control menu map 12 8 Control menu 14 8 1 Fixture Address 14 8 2 Slave control 14 8 3 Fixture informations 14 8 4 Personality 15 8 5 Manual mode 16 8 6 Test sequences 16 8 7 Stand alone setting 16 8 8 Reset function 17 8 9 Special functions 17 9 Low power mode 18 10 Error and information messag...

Страница 3: ... to the device are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power switch is set to Off position before you connect the device to the mains ...

Страница 4: ...place is blocked when rigging derigging or servicing the fix ture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fas tened The maximum ambient temperature 45 C must never be exceeded Operate the device only after having familiarized with i...

Страница 5: ... Rotating plate 4 Top covers Rear panel of the fixture 5 Power switch 6 Power cord 7 Fuse holder 8 3 pin DMX output 9 3 pin DMX input 10 5 pin DMX output 11 5 pin DMX input Front panel of the fixture 12 Mode button 13 Enter button 14 Up button 15 Down button 16 Display ...

Страница 6: ... US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth 4 2 Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency The wrong settings can cause poor performance or demage of the fixture The factory settings are printed next to the power switch If you want to change the power sup...

Страница 7: ...all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people If the device shall be lowered from the ceiling or high joists professional trussing systems have to b...

Страница 8: ... holders on the bottom of the base by inserting both quick lock fasteners 3 into the holes of the base and tighten fully clockwise 3 Fasten the safety cable 2 through the two apertures on the bottom of the base and over the trussing sys tem 1 Clamp 2 Safety cable 3 Quick lock fastener 4 Omega holder advertising plate Omega holder safety cable fixing clamp clamp rotating plate ...

Страница 9: ... the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ω resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX out...

Страница 10: ...from 0 1 s to 25 5 s step proportional proportional 4 0 129 130 139 140 199 200 255 Pan functions Standard operation fixture is controlled by channels 1 2 and 3 Reset of the pan Forward pan rotation speed is controlled by channel 3 Backward pan rotation speed is controlled by channel 3 step step step step Note for programming If you want to keep the same direction of the pan movent around 0 DMX 25...

Страница 11: ...rams which can be different for every fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture the fixture may be set to the master slave mode or controller mode or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of the...

Страница 12: ...SEt DM In PAn 0 255 F PAn 0 255 SPEd 0 255 Func 0 255 VErS IC1 b IC2 b IC3 b PErS r PAn On Off dISP turn On Off d On On Off d Int 20 100 FEEd On Off MI SE 1 10 20 FAn S Auto HIGH PA Mo SP Mo ti Mo In Po PAn 0 255 Func 0 255 Stor dF SE MAn M PrE C Pan Pan 1 Pan3 SPEd SPd 1 SPd 5 Func Fun 1 Fun 3 MAn C Pan 0 255 F PAn 0 255 SPEd 0 255 Func 0 255 ...

Страница 13: ...13 tESt St AL Audi On Off Auto Off tESt PrG 1 PrG 2 PrG 3 PLAY tESt PrG 1 PrG 2 PrG 3 Edit PrG 1 PrG 2 PrG 3 St 01 St 99 Pan 0 255 S tim 0 1 25 5 s COPY rESE SPEC CodE uPd M No Yes ...

Страница 14: ...bL deactivates master slave setting 8 2 Slave control This function allows you to control the slaves from the master s control panel in a master slave operation Select this function from the main menu and press ENTER Browse the list of all connected slaves SL C 1 SL C 9 by pressing UP or DOWN Select the desired slave and press ENTER button The matching slave control panel is available from the mas...

Страница 15: ...function allows you to change the display settings turn Select this function to turn the display by 180 d On This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int Select this function to adjust the display intensity 20 min 100 max bL Co Blackout during movement correction Select this function to enable the b...

Страница 16: ... values 8 5 Manual mode Select this menu to call up presetted positions of channel effects or direct control channel effects PrE C Presetted effect control Select this menu to call up presetted positions of the channel effects Man C Manual effect control Select this menu to control effects by control buttoms on the control board PAn a coarse pan movement F PAn a fine pan movement SPEd a pan speed ...

Страница 17: ...nd press ENTER 2 Press UP or DOWN to select the desired fixture MASt SLA 9 and press ENTER button 3 Press UP or DOWN to select the desired program step St 01 St 99 and press ENTER button 4 Press UP or DOWN to select the desired item and press ENTER button Now you can edit by UP or DOWN buttons the DMX value 0 255 for selected item P End a total number of the program steps value 1 99 This value you...

Страница 18: ...ect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update isn t checked all processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process Updat...

Страница 19: ...ror The message informs you that the fixture was addressed as a master and DMX signal is connected to its input Disconnect the DMX controller from fixture s input and address the fixture as the master again 11 Technical specifications Power supply EU model Voltage 208 230 240V AC 50 60Hz Fuse T 630 mA 230V US model Voltage 100 120 208 230 240 V AC 50 60Hz Fuse T 1 25 A 120V Power consumption 25 VA...

Страница 20: ...onnect from the mains before starting any maintenance work More complicated maintenance and service operations are only to be carried out by authorized distributors Replacing the fuse Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure 1 Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the housing anti cl...

Страница 21: ...21 ...

Отзывы: