10. Error and information messages
Mb.Er.
This messsage informs you that the main PCB does not communicate correctly with the Control Board.
Fr.Er.
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices.
In these cases the message does not affect the fixture operating!
Po.Er.
This message will appear if the fixture was shortly disconnect from the mains.
PA.Er.
(Pan movement error)
This message will appear after the reset of the fixture if the pan plate’s magnetic-indexing circuits malfunction
(sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
pan plate is not located in the default position after the reset.
MA.Er.
(Master error)
The message informs you that the fixture was addressed as a master and DMX signal is connected to its
input.Disconnect the DMX controller from fixture's input and address the fixture as the master again.
11. Technical specifications
Power supply:
EU-model-Voltage......................208/230/240V AC, 50/60Hz ~
-Fuse.........................T 630 mA@230V
US-model-Voltage......................100/120/208/230/240 V AC, 50/60Hz ~
-Fuse.........................T 1.25 A@120V
-Power consumption....25 VA
Electronics:
-Addressing,special functions setting via control panel with 4-digit LED display
-Readout fixture usage,receiving DMX values,temperature, etc
-Built-in analyzer for easy fault finding,error messages
-Bilt-in demo sequences
-Silent cooling,
-Master/slave operation
-Digital serial input DMX-512
-4 control -channels
Pan
-16 bit movement resolution
-Automatic pan position correction
-Remotely controllable speed of pan movement for easy programming
-Movement control:tracking and vector
Rigging
-Stands directly on the floor
-Mounts horizontally or vertically with 2 Omega brackets
-2 truss orientation
-Safety chain/cord attachment point
Max.load
10 kg
Max.ambient temperature
45°C