
6
4. Installation
Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulatio
n.
4.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin MMX Blade is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz
AC power source from 00-40 Volts.
For use with 100-120 V supplies, the main 8 A fuse has to be exchanged for 15 A fuse which is enclosed
in the packing.
To install the 15 A fuse:
1. Disconnect the fixture from AC power.
2. Unscrew the fuse holder on the rear panel of the base with a flat-tip screwdriver from the housing
(anticlockwise).
3. Remove the 8 A fuse from the fuse holder.
4. Put the 5 A fuse in the fuse holder.
5. Replace the fuse holder in the housing and screw it fully clockwise.
Install a suitable plug on the power cord (if it is needed), note that the cores in the power cord are coloured
according to the following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
Содержание Robin MMX Blade
Страница 1: ... Version1 1 ...
Страница 15: ...15 Framing shutters identification ...
Страница 32: ...32 Location of the fans ...
Страница 36: ...36 Photometric charts ...
Страница 37: ...37 ...
Страница 47: ...39 ...