3. Installation
Fixtures must be installed by a qualified electrician in accordance with
all national and local electrical and construction codes and regulations.
3.1 Connection to the mains
The Robin CycBar UV is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 100-240 V.
If you need to install a cord cap on the power cable to allow connection to power outlets, install a grounding-type
(earthed) plug, following the plug manufacturer’s instructions.
The cores in the power cable are coloured according to the following table
.
Core (Eu)
Core (US)
Connection
Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
This device falls under class one and must be grounded!
Design of the Robin CycBar UV allows to connect several fixtures to AC mains power in one interconnected daisy
chain using power input/output connectors. Needed daisy chain cables are stated in the chapter “Technical
specifications “
Max. number of connected fixtures depends on the AC mains power voltage and fixture version:
CE:
US:
29 fixtures at power supply= 230V
17 fixtures at power supply= 230V
26 fixtures at power supply= 208V
15 fixtures at power supply= 208V
13 fixtures at power supply= 120V
7 fixtures at power supply= 120V
Actual numbers of fixtures may differ from values stated above as you have to take into account the length of
supply cables, circuit breaker etc. at projecting of the fixtures installation.
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by qualified staff!