Страница 2: ...1 6 Control menu 13 6 1 Fixture Address 13 6 2 Fixture information 13 6 3 Personality 14 6 4 Manual mode 15 6 5 Test sequences 15 6 6 Stand alone setting 15 6 7 Special functions 16 7 RDM 18 8 Technical specifications 19 9 Cleaning and maintenance 21 9 1 Disposing of the product 21 10 Extract from a test report of Brno University Of Technology Light laboratory 22 10 1 Measurement results for all L...

Страница 3: ...use 1 Safety instructions THIS LUMINAIRE IS DESIGNED WITH UV LEDS AND MUST BE INSTALLED IN COMPLIANCE WITH COMPOTENT TECHNICAL DIRECTIONS TO PREVENT THE USER S EYE AND BARE SKIN FROM EXPOSURE TO HARMFUL UV RADIATION CE LUMINAIRE EST CONCU POUR ETRE UTILISE AVEC DES LED UV ET DOIT ETRE INSTALLE EN STRICTE CONFORMITE AVEC LES INSTRUCTIONS AFIN D EVITER QUE LES YEUX OU LA PEAU L UTILISATEUR NE SOIENT...

Страница 4: ...he fixture has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation of water might damage your device Leave the device switched off until it has reached room temperature Avoid brute force when installing or operating the fixture When choosing the installation spot please make sure that the fixture is not exposed to extrem...

Страница 5: ...to IP 65 by mating with related X HD cable connectors They cannot stay disconnected outdoor DMX output connector XLR female at the last fixture in a DMX line has to be covered with the rubber cap before inserting a terminator The rubber cap does not supply the terminator The XLR terminator male has to be water protected If the fixture is to be outdoor without connecting to DMX line always intercon...

Страница 6: ...n Green Earth This device falls under class one and must be grounded Design of the Robin CycBar UV allows to connect several fixtures to AC mains power in one interconnected daisy chain using power input output connectors Needed daisy chain cables are stated in the chapter Technical specifications Max number of connected fixtures depends on the AC mains power voltage and fixture version CE US 29 f...

Страница 7: ...y of a possible installation do not install the device and consult installation with an expert Truss installation 1 Bolt clamps 1 to the omega holders 2 with M12 bolt and lock nut through the hole in the omega holder 2 Fasten the omega holders to the brackets of the Robin CycBar by inserting both turn quick locks 3 into the holes of the brackets and tighten fully clockwise 3 Clamp the fixture on a...

Страница 8: ...Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain 2 Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture 3 Always connect the DMX output with the input of the next fixture until all fixtures are connected Do not overload the link Max 32 fixtures may be connected on a DMX link Caution Terminate t...

Страница 9: ...e menu item unLi SPEC rAdI unLi 3 5 Inserting the black glass Design of the Robin CycBar UV allows you inserting black glass in front of the glass cover of the CycBar UV The black glass consisst of four parts three shorter and one longer Always insert all parts of the black glass into fixture Note To keep declared ingress protection do not disassemble side covers of the fixture To insert black gla...

Страница 10: ...hutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open Random strobe effects from slow to fast Shutter open step step proportional step proportional proportional step proportional step 1 2 0 255 Dimmer Dimmer intensity from 0 to 100 proportional 2 3 0 255 Dimmer fine Fine dimmer intensity from min to max pro...

Страница 11: ...evel 5 Menu Level 6 A001 dM Ad 001 512 dM Pr Mod 1 Mod 2 InFo Poti totl rSEt VErS ICI IC2 tEMP Cur t tEM b tEM L Hi tE tEM b tEM L rSEt tEM b tEM L DM In Stro 0 255 dimr 0 255 F dim 0 255 PErS dM Pr Mod1 Mod 2 dM In VirE VirL VrLo M F ti 0 0 0 1 25 2 dISP d On On Off d Int 6 100 turn diM L S9u LIn tEM u C F In Po Stro 0 255 ...

Страница 12: ...u Level 5 Menu Level 6 dimr 0 255 F dim 0 255 SAVE dF SE MAn M Stro 0 255 dimr 0 255 F dim 0 255 tESt St AL Auto OFF tESt PrG1 PrG3 PLAY tESt PrG1 PrG3 Edit St 01 P End 1 40 Stro 0 255 St 40 F tim 0 25 5 sec S tim 0 25 5 sec COPY SPEC rdML rdMH rAdI SiGn unLi HOLd On OFF uPd ...

Страница 13: ... 512 data is received or not If there is no data received at the DMX input the display will start to flash with actually set address DM Pr DMX preset Select this menu item to set a desired DMX mode Please refer to the chapter DMX protocol for detail description of each DMX mode Mod 1 2 control channels Mod 2 3 control channels 6 2 Fixture information Use this menu to read useful information about ...

Страница 14: ...a Wireless DMX convecter M F ti Max Fade time Select this menu item to set a desired max fade time 0 25 5 sec This adjusted fade time influences fade of dimmer during DMX operation If time between two receiving DMX values is than fade time set in the item MF ti the entire adjusted fade time will be used If time between two receiving DMX values is than fade time set in the item MF ti the adjusted f...

Страница 15: ...ler which will show you some possibilities of using the Robin CycBar UV 6 6 Stand alone setting The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Auto Automatic playback This function allows you to select ...

Страница 16: ...menu item shows the second part of the RDM identification code rAdI SiGn the menu serves for reading of the state of wireless operation only Wireless DMX unLi the item serves for unlinking the fixture from the transmitter only Wireless DMX version HOLd If the function is on the last received DMX values are held in case that DMX data receiving was interrupted e g disconnected DMX controller uPd M U...

Страница 17: ...Select correct COM number if you use a Flash cable RS232 DMX or select Robe Universal Interface if you use the Robe Universal Interface Robe Universal Interface WTX and then click on the Connect button 7 If the connection is OK click the Start Uploading button to start software uploading It will take several minutes to perform software update If the option Incremental Update is not checked all pro...

Страница 18: ... RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for the Robin CycBar UV is the following Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_VERSION_LABEL DMX_START_A...

Страница 19: ...s Wireless DMX RDM module only for wireless DMX version of the Robin CycBar UV Compliance with USITT DMX 512 1986 1990 and 512 A Full DMX fidelity and frame integrity Auto sensing of DMX frame rate and frame size 5ms DMX latency Operational frequency range of 2402 2480 MHz Producer LumenRadio Strobe Strobe effect with variable speed max 20 flashes per second Pre programmed random strobe pulse effe...

Страница 20: ...278 Daisy Chain PowerCon TRUE1 In Out EU 0 75m outdoor P N 13052 279 Daisy Chain PowerCon TRUE1 In Out US 0 75m outdoor P N 13052 280 Daisy Chain PowerCon TRUE1 In Out EU 2m outdoor P N 13052 281 Daisy Chain PowerCon TRUE1 In Out US 2m outdoor P N 13052 405 Mains Cable powerCON TRUE1 In Schuko 2m Indoor P N 13052 406 Mains Cable powerCON TRUE1 In US 2m Indoor P N 13052 445 Mains Cable powerCON TRU...

Страница 21: ...ut very quickly For cleaning use a wet clout or an air jet Do not use solvents or any other aggressive cleaning fluid Maintenance and service operations are only to be carried out by a qualified person or Anolis service worker only Should you need any spare parts please use genuine parts 9 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of i...

Страница 22: ...hnology Light laboratory 10 1 Measurement results for all LEDs with clear glass max power Evaluted according ČSN EN 62471 ČSN EN 62471 5 IEC TR 62778 ANSI IESNA RP 27 3 07 Fixture at a distance which produces illuminance of 500 lx Results for Robin CycBar UV are in bold frame ...

Страница 23: ...value is not used to evaluate risk All LEDs on max power Calculated values of illuminance E actinic ultraviolet irradiance Es ultraviolet irradiance EUVA depending on distance I Measured values From these values are calculated other values Calculated values for illuminance of detector E 500lx These values are decisive for determining of hazard group ...

Страница 24: ...nt results for all LEDs with black glass max power Evaluted according ČSN EN 62471 ČSN EN 62471 5 IEC TR 62778 ANSI IESNA RP 27 3 07 Fixture at a distance which produces illuminance of 500 lx Results for Divine 60 UV are in bold frame ...

Страница 25: ...traviolet irradiance EUVA depending on distance I Measured values From these values are calculated other values Calculated values for illuminance of detector E 500lx These values are decisive for determining of hazard group Full report from the Light Laboratory on request Specifications are subject to change without notice August 23 2018 Copyright 2018 Robe Lighting All rights reserved Made in CZE...