4.5 Replacing the heavy frost
Unplug from mains before frost installing!
1. Disconnect the fixture from mains and allow it to cool for 20 minutes.
2. Move the head to the position that signs on the lamp cover (1) lead up
3. Remove plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
4. Move the zoom module
(2) towards front lens to get access to heavy frost (3).
5
. The holder (4) of the frost film is fastened to the frost holder (8) by means of the four magnets (5). Grip the
holder (4) and carefully tilt it out to break a force of magnets (5) on the frost holder (8).
6
. Insert a new frost module into the frost holder (8). Check, that both slots (6) snapped correctly into
two protrusions (7) on the holder (4)
7. P
lace the plastic cover back on the fixture before applying power.
Note: If you look into the fixture through a front lens (
fixture´s lamp must be off
), you can see the heavy frost
number- white number at a black holder. It is an easy way how to find out a type of installed heavy frost in the
fixture without taking head cover down. Heavy frost No. 20 is installed in the fixture as default, another frosts
10° and 30° are included as standard accessories.