7. Cleaning and maintenance   

 

Disconnect from power before starting any maintenance or cleaning work 

 

Keep the fixture clean, especially light source and the ribbed housing. 

Maintenance and service operations are only to be carried out by a qualified person. 

Should you need any spare parts, please use ROBE OEM parts. 

 

7.1 Software update  

Software update by means of the Robe Uploader. 

The ROBE Uploader is a software for automatized software update of Robe and Anolis fixtures. It takes advantage 

of RDM support. 

Note: Software update by means of the Robe Uploader cannot be used if fixtures are connected by means of DALI 

connection. 

 

Example of connection: 

 

 

Содержание Anolis Ambiane XP56

Страница 1: ...Version 2 5 QR code for user manual ...

Страница 2: ...trol 7 2 2 0 10V control 8 3 RDM 8 4 Optional accessories installation 10 4 1 Top frame installation 10 4 2 Louver installation 11 4 3 False ceiling mounting adaptor istallation 12 5 DMX protocols 13 6 Technical specifications 15 7 Cleaning and maintenance 22 7 1 Software update 22 7 2 Disposing of the product 23 ...

Страница 3: ...a around the unit non IC rated fixture Avoid looking directly into the light beam at close range Suitable for fastening on Unsuitable for covering by heat insulation non flammable surfaces only material Immunity of the equipment is designed for electromagnetic environments E1 E2 E3 according to the standard EN55103 2 ed 2 Electromagnetic compatibility Product family standard for audio video audiov...

Страница 4: ...tant The Top frame for Ambiane XP Recessed has to be under lower ceiling before its inserting on the housing of the Ambiane XP56 Recessed 2 The yoke 2 with three holes serves for fastening the Ambiane XP56 Recessed to the ceiling construction To move the yoke 2 up down release both screws 3 4 on each side of the unit To tilt the yoke in range of 90 from the vertical axis release the screw 3 on eac...

Страница 5: ... XP The secondary power input serves for a backup power in case that primary power failed If both power inputs are under voltage the primary power has a priority and the secondary power is disabled In case of primary power loss the secondary power is enabled If the fixture is supplied via the secondary power the light output of the fixture is a white colour 3200K RGBW TW version and its light inte...

Страница 6: ...ion Power Power Secondary power connection DMX connection Connector D D 0V Function Data Data Data ground shielding 0 10V connection Connector D 0V Function 10V 0V DMX connectors are used for 0 10V control Max length of the supply cable between the Ambiane XP56 Recessed and the Ambiane Power XP and Ambiane Power Rack is defined by the following table Circular cross section of wire Max cable length...

Страница 7: ...LI operation and last coming command is a DMX command which switches the fixture to DMX operation Next command is a DALI command and switches the fixture to the DALI operation etc If you need the permanent DALI operation you have to send a DALI command 8 to the fixture DMX control The DMX start address is the first channel used to receive instructions from the DMX controller The address may be any...

Страница 8: ...ecessed only 3 RDM This fixture supports RDM operation RDM Remote Device Management is a bi directional communication protocol for use in DMX 512 control systems it is the new open standard for DMX512 device configuration and status monitoring RDM allows you to set a DMX address select DMX mode readout software version of the fixture etc It is also used for fixture software update by means of the ...

Страница 9: ...Ambiane XP56 Recessed 9 SLOT_INFO SLOT_DESCRIPTION DEFAULT_SLOT_VALUE PARAMETER_DESCRIPTION ...

Страница 10: ...wer ceiling 1 if it is required Note The Top frame has to be placed under lower ceiling before sliding it onto the housing of the Ambiane XP56 Recessed 1 Slide the Top frame 2 onto the housing of the Ambiane XP56 Recessed through the opening in the lower ceiling 2 Secure the Top frame in a right position by means of two spring locks 3 which have to lean against ceiling 1 ...

Страница 11: ...rews 1 on both sides of the Ambiane XP56 Recessed 2 Slide the louver 2 onto the housing of the Ambiane XP56 Recessed 3 Secure it by means of two socket head screws M4 x 14 3 screws are enclosed with the louver on both sides of the housing of the Ambiane XP56 Recessed ...

Страница 12: ...by means of three holes 4 of diameter of 5 5 mm The lower ceiling or another structure intended for installation of the false ceiling mounting adaptor s must safely hold at least 5 times weight of the Ambiane s placed on it 3 Insert the Ambiane XP56 Recessed into the false ceiling mounting adaptor and screw its yoke to the false ceiling mounting adaptor via the mounting hole 6 of a diameter of 8mm...

Страница 13: ...ncorrected white Minus green uncorrected white Uncorrected white 128 default Uncorrected white Plus green step proportional step proportional 10 2 0 1 10 11 20 21 255 Colour temperature correction CTC No function 0 default Tungsten dimming 2700 K Tungsten dimming 3200 K Colour temperature changing 2700 K 6500 K step step step proportional 11 3 5 0 255 Dimmer Light intensity coarse 0 100 proportion...

Страница 14: ...cessed 14 Variant TD PW version 1 1 Mode 1 Channel Mode 2 Channel DMX value Function Type of control 1 1 0 255 Dimmer Light intensity coarse 0 100 proportional 2 0 255 Dimmer Fine Light intensity min max proportional ...

Страница 15: ...Mode 3 3 Mode 4 6 Mode 5 DMX channels TW variant 2 Mode 1 3 Mode 2 DMX channels TD PW variant 2 Mode 1 2 Mode 2 Power supply Ambiane Power XP Ambiane Power Rack Operating ambient temp range 20 C 40 C 4 F 104 F Operating Temperature 70 C Ambient 40 C 158 F Ambient 104 F Total heat dissipation 382 BTU h calculated Cooling convection Housing High Pressure Die Cast Aluminium Body Weight Ambiane XP56 2...

Страница 16: ... 16 Ambiane XP56 45 L2 370 14 9 16 Ambiane XP56 60 L2 341 13 7 16 Dimension L1 depends on U holder position Ambiane XP56 20 30 L1 448 17 5 8 528 20 13 16 Ambiane XP56 45 L1 423 16 5 8 503 19 13 16 Ambiane XP56 60 L1 394 15 1 2 474 18 11 16 Ambiane XP56 Recessed with Top frame ...

Страница 17: ...Ambiane XP56 Recessed 17 Ambiane XP56 Recessed with Louver 5 Ambiane XP56 Recessed with Louver 10 ...

Страница 18: ...Ambiane XP56 Recessed 18 Ambiane XP56 Recessed in the false ceiling mounting adaptor ...

Страница 19: ...Ambiane XP56 Recessed 19 False ceiling mounting adaptor ...

Страница 20: ...Ambiane XP56 Recessed 20 Top frame for Ambiane XP Recessed Louver 5 for Ambiane XP Recessed ...

Страница 21: ...ptional accessories Trim for Ambiane XP Recessed RAL 9005 P N 10980572 Louver 10 for Ambiane XP Recessed RAL9005 P N 10980533 Louver 5 for Ambiane XP Recessed RAL9005 P N 10980534 False Ceiling Mounting Adaptor for Ambiane XP56 Recessed P N 10980599 Ambiane Power XP P N 10063710 Ambiane Power Rack P N 10063951 Ambiane Power Rack US P N 10063873 ...

Страница 22: ...nly to be carried out by a qualified person Should you need any spare parts please use ROBE OEM parts 7 1 Software update Software update by means of the Robe Uploader The ROBE Uploader is a software for automatized software update of Robe and Anolis fixtures It takes advantage of RDM support Note Software update by means of the Robe Uploader cannot be used if fixtures are connected by means of DA...

Страница 23: ...ader software and user manual is available at https www robe cz robe uploader If you do the software update by means of the Robe Uploader switching fixtures to the update mode and from the update mode is made automatically 7 2 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes Specification...