![Robam JZT B110 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/robam/jzt-b110/jzt-b110_user-manual_1468423014.webp)
12
Gas Hob
Gas leakage
(odor of gas)
Abnormal
combustion
or noises
Close the switch knob
Connect the hose properly or replace it
The switch knob is not closed
The hose is not proper connected
or has cracks
Faults
Ignition failure
Flame extinct
after releasing
Solutions
Close the switch knob of stove and then open
the valve of gas source
Carry out ignition repeatedly to exhaust the air
in pipe
Straighten unblock or replace the hose
,
Clean the head
Adjust the distance between the ignition
electrode and the receiving end at around 4mm
The cooper core and cooper cap must be put
in place
Narrow down the throttle
After ignition hold and press the switch knob
,
for3~5 seconds(to the maximum extend)and
then release it
Causes
The cooper core and cooper cap are
not in place
The knob is not pressed to the
maximum extend
Bending blocking or pressing of hose
,
Air in gas pipe
The switch of gas source closes
The porcelain head of ignition electrode
is not clean
Improper distance between the ignition
electrode and the receiving end
The throttle is so wide that causes lifted
flame
Improper adjustment of throttle
Blockage of burner or flame outlet
The gas used is not in consistence
with the gas type marked on stove
Unstable gas pressure water in hose
,
Adjust the throttle
Remove the blockage
Select correct stove
Remove the water in hose
Natural Gas Regulator
Natural Gas Regulator
Annex Name
Manual
Quantity
1
1
Common Faults And Solutions
Accessories