background image

Rhein - Nadel Automation GmbH 

14.04.2014 

Bowl feeder VT-BA-SRC63-100-GB 

 

 

Notice

 

All vibratory bowl feeders listed in the table may only be operated in connection with a RNA control unit 
at a mains voltage of 230V/50Hz. Special voltages and frequencies see separate data sheet. 

 

1  Technical data 

 

Vibratory bowl feeder type 

1)

 

 

SRC-N 63-2 

SRC-N 100-2 

Dimensions ø x height

 

in mm 

60 x 65 

90 x 82 

Weight

 

in kg 

0,8 

1,8 

Insulation type

 

 

IP 54 

IP 54 

Connecting cable length

 

in m 

1,4 

1,4 

Power consumption 

2)

 

 

in VA 

11 

Current consumption 

2)

 

 

in A 

0,04 

0,055 

Magnet nominal voltage 

2)

 /frequency

 

in V / Hz 

230 / 50 

230 / 50 

Air gap [mm]

 

in mm 

0,3 - 0,4 

 

0,3 - 0,4 

Number of magnets

 

 

Vibration frequency

 

in Hz/min

-1

 

100 / 6000 

100 / 6000 

1)

  The last figure of the type identification shows the Vibration frequency: 1=50Hz (black mains cable),            

      2=100 Hz (grey mains cable) 

2)

  For special voltages (voltage, frequency) see type plate at the magnet

 

 

 
Pin assignment

 

 

 
 

 

 

 
2  Safety instructions 

 
The conception and production of our vibratory bowl feeders has been carried out very careful, in order to 
guarantee a trouble-free and save operation. You too can make an important contribution to job safety. 
Therefore, please read this  short operating instruction completely, before starting the machine. Always ob-
serve the safety instructions! 
 
Make sure that all persons working with or at this machine carefully read and observe the following safety 
instructions! 
 
This operating instruction is only valid for the types indicated on the front page.  
 

 

Notice

 

This hand points to information that gives you useful tips for the operation of the vibratory bowl feeder. 

 
 
 

The bridge has to be installed in connection 3+4 

 

Содержание SRC-N 100-2

Страница 1: ...Operating instructions Vibratory bowl feeder SRC N 63 2 SRC N 100 2 BA Rhein Nadel Automation GmbH...

Страница 2: ...Stockkeeping of spare parts and after sales service Seite 8 8 What to do if Seite 8 Instructions for trouble shooting Declaration of conformity as defined by Low voltage directive 2014 35 EU Herewith...

Страница 3: ...of the type identification shows the Vibration frequency 1 50Hz black mains cable 2 100 Hz grey mains cable 2 For special voltages voltage frequency see type plate at the magnet Pin assignment 2 Safet...

Страница 4: ...ee page 1 2 Make sure that the connected load of the vibratory bowl feeder control unit and power supply corresponds to each other Notice The vibratory bowl feeder may only be operated in perfect cond...

Страница 5: ...Vibratory bowl feeders are used for the actuation of sorting machines The actuation takes place by electro magnets The following schematic diagram shows the function of a vibratory bowl feeder The dri...

Страница 6: ...By the turning knob the conveying capacity of the sorting unit is set 4 Mounting The device is completely mounted The vibrator has to be screwed on a strong subassembly in a dry room Ambient temperatu...

Страница 7: ...l 1 Fit the unit on a solid subsurface 2 Loosen the fixing screw of the magnet coil Screw is fitted laterally at the counter mass across the cable outlet 3 Adjust the air gap with the height adjusting...

Страница 8: ...ntrol unit or the connecting terminal box may only be opened by an electrician Before opening the a m devices the mains plug must be unplugged Trouble Possible cause Remedy Vibratory bowl feeder does...

Страница 9: ...Schw bisch Hall Tel 49 0 791 9460098 0 Fax 49 0 791 9460098 29 Email info psa zt de HSH Handling Systems AG Wangenstr 96 CH 3360 Herzogenbuchsee Tel 41 062 95610 00 Fax 41 062 95610 10 Internet www r...

Отзывы: