RNA SRC-B 200-2 Скачать руководство пользователя страница 13

Rhein-Nadel Automation GmbH

 

 

 

 

13  

VT-MA-SRC 160-800-EN_2019 / 20.03.2019 SJ 

When you loosen the spring fastening screw you can observe a change in feeder speed. 
The following graph shows the resonance curve of a vibratory feeder. 
 

 

 

 

Notice

 

The  resonance  frequency  of  the  vibratory  feeder  must  not  be  equal  to  the  mains  frequency,  it  should  be 
lower than the driving frequency of the current. 

 
If the feeder speed decreases after you loosen the spring fastening screw, proceed as described in 

section 5.1

 
If, on the contrary, the feeder speed increases, proceed as described in 

section 5.2

 

 

Notice

 

Tuning  is  facilitated  by  the  use  of  an  electronic  frequency  controller  that  is  part  of  our  standard  product 
range. 

 
The vibratory feeder should be tuned so that the desired feeder speed is obtained with a controller setting of approx. 
80%. This is to ensure sufficient magnetic saturation. 

5.1. 

Feeder speed decreases? 

Install additional springs. Start by adding one spring (including spacers) to 

one

 spring pack. If the feeder speed con-

tinues to decrease after you loosen a fastening screw anew, install additional springs one by one progressively in an-
other spring pack until the desired speed is obtained with the controller set at 70 - 80%. 

5.2. 

Feeder speed increases? 

Remove springs. Start by removing one spring (including spacers) from 

one

 spring pack. If the feeder speed continues 

to increase  after  you  loosen  a  fastening  screw  anew,  remove  springs  one  by  one  progressively  from  another  spring 
pack until reaching a range where the feeder speed decreases when you loosen the spring fastening screws. In this 
range the resonance frequency of the system is lower than the driving frequency of the current. Now proceed with the 
actual tuning procedure as described in Section 5.1. 
 

 

Notice

 

As the tuning procedure is done with the enclosure removed, be sure to add one more spring after finding 
the optimum setting. This compensates the influence of the sheet metal enclosure on the frequency. 
With type SRC-N 800 feeders, install 6 additional springs (one each in every 2nd spring pack).  

 

Objective of the tuning procedure:  
To set a stable feed rate matching the requisite amount of product. 

 
When  the  desired  feeder  speed  is  obtained  at  a  controller  setting  of  80  %,  the  feeder  speed  must  always  decrease 
when the spring fastening screw is loosened. 
 

 

Notice

 

Make sure that the number of springs per spring pack will not deviate by more than 2 

– 3 springs. Other-

wise the feeder speed at the circumference of the bowl is no longer constant. 

 
 

 

Feed rate 

Desired feeder speed 

Resonance frequency of the system 

Resonance curve 

Spring force (number of springs) increasing 

Содержание SRC-B 200-2

Страница 1: ...Installation and Operating Instructions Vibratory Feeders SRC N 160 2 SRC N 200 2 SRC B 200 2 SRC N 250 2 SRC B 250 2 SRC N 400 1 SRC N 400 2 SRC N 630 1 SRC N 800 1 SRHL 400 1 SRHL 400 2...

Страница 2: ...data 4 2 Safety directives 7 2 1 Applicable directives and standards 8 3 Design and functional description 8 4 Shipment and installation 10 5 Commissioning 12 5 1 Feeder speed decreases 13 5 2 Feeder...

Страница 3: ...ow Voltage Directive 2014 35 EU We hereby declare that the product meets the following requirements Low Voltage Directive 2014 35 EC Applied harmonised standards DIN EN 60204 T1 Remarks We assume that...

Страница 4: ...5000714 WZUW 080 35000721 WZUW 080 35000721 WZAW 060 35000727 WZAW 060 35000727 YZAW 080 35000739 Magnet colour black black black black black red Air gap mm 0 3 0 5 0 4 0 5 0 4 0 5 1 1 2 1 1 2 2 3 2 8...

Страница 5: ...5 0 5 0 5 1 4 Power input2 VA 786 1140 1060 1000 1700 Current 2 A 4 05 5 7 5 3 5 8 5 Nominal magnet voltage 2 frequency 220V 50Hz Number of magnets 3 2 2 4 4 Magnet type Article number WZAW 080 350007...

Страница 6: ...Rhein Nadel Automation GmbH 6 VT MA SRC 160 800 EN_2019 20 03 2019 SJ Pin assignment With jumper The jumper must be inserted between connections 3 4...

Страница 7: ...ludes observance of the operating instructions and compliance with the maintenance rules For the technical data for your vibratory feeder please refer to the table Technical Data Section 1 Make sure t...

Страница 8: ...enting parts The driving force is provided by an electromagnetic coil The figure below is a schematic representation of a vibratory feeder Driving magnet D is rigidly connected to counter mass F When...

Страница 9: ...200 SRC N 250 SRC B 250 SRC N 400 SRHL 400 SRC N 630 SRC N 800 The controller has a 5 pin connector on its front panel for connection to the vibratory feeder Connector pin assignment is shown in the...

Страница 10: ...plastic cap and domed nut M16 Attention Do not sling or handle the vibratory feeder at or on the orienting device Take care that the vibratory feeder cannot collide with other objects during handling...

Страница 11: ...20 3 x 120 M 8 SRC B 250 220 3 x 120 M 8 SRC N 400 1 350 3 x 120 M 10 SRC N 400 2 350 3 x 120 M 10 SRHL 400 1 350 3 x 120 M 10 SRHL 400 2 350 3 x 120 M 10 SRC N 630 1 560 3 x 120 M 10 Table Drilling d...

Страница 12: ...r vibratory feeders that are supplied as a completely set up system the optimum feed rate has been fac tory set It is marked with a red arrow on the dial of the rotary knob In this case set the rotary...

Страница 13: ...0 5 2 Feeder speed increases Remove springs Start by removing one spring including spacers from one spring pack If the feeder speed continues to increase after you loosen a fastening screw anew remove...

Страница 14: ...missible sound insulating hoods can be installed which we can offer on request see our catalogue 6 Maintenance Vibratory feeders basically require no maintenance They should only be cleaned when soile...

Страница 15: ...ctor there is a risk of damage to the controller and magnet Set controller to 80 Check that coding in plug connector of the controller is correct see rating plate and Technical Data Section 1 The vibr...